Inspections for the day of: Thursday, November 5, 2015.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE15-01812 Electrical Rough-In11/4/201511/5/201511/5/2015 3:31:47 PMPPASS
Underground inspection for vacuum lights. Phone #: ###-#### Inspection requested via web by William Salts Multiple locations on southside of building. Areas noted rough in ok cover.
ELE14-03133 Final11/4/201511/5/201511/5/2015 3:09:58 PMPPASS
Call 15 minutes before // Brad Phone #: ###-#### All GFCI protective devices in readily accessible locations, Corrections have been made. Final ok
ELE15-02778 Final11/5/201511/5/201511/5/2015 2:45:07 PMPFAIL
Phone #: ###-#### Inspection requested via web by Eric Schroeder 408.4- Circuit directory shall be complete.
408.6- Unused breaker spaces shall be closed.
Confirm USB/ duplex receptacles are tamper resistant type.
ELE15-03571 Rough-In Permanent Service11/5/201511/5/201511/5/2015 2:08:38 PMPPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn Rough in ok cover p/s u/g n ok
ELE15-03579 Electrical Rough-In11/5/201511/5/201511/5/2015 1:36:09 PMPFAIL
Michael Phone #: ###-####
210.52- Shall have receptacle outlet located with in 24" of left side of range.
250.64(C)- Splice for grounding electode conductor shall be with irriversible connector listed.
Wiring for smoke detectors shall be completed.
ELE15-03592 Temporary Service11/5/201511/5/201511/5/2015 12:17:17 PMPPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn t/s u/g n ok
ELE15-03591 Temporary Service11/5/201511/5/201511/5/2015 11:52:02 AMPPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn t/s u/g n ok
ELE15-03587 Temporary Service11/5/201511/5/201511/5/2015 11:19:40 AMPPASS
Phone #: ###-#### Inspection requested via web by TOM BICANDI t/s u/g n ok
ELE15-02359 Final11/4/201511/5/201511/5/2015 11:04:32 AMAPASS
Robert Phone #: ###-#### Heat pump final ok
ELE12-01934 ELE-Aging Inspection11/5/201511/5/201511/5/2015 11:01:13 AM DONE
Waiting for contractor to provide access
ELE12-02132 ELE-Aging Inspection11/5/201511/5/201511/5/2015 11:00:33 AM DONE
Still under construction
ELE15-03400 Permanent Service11/4/201511/5/201511/5/2015 10:24:39 AMAPASS
Phone #: ###-#### Inspection requested via web by daniel bibikov
p/s u/g n ok
ELE15-03566 Rough-In Permanent Service11/4/201511/5/201511/5/2015 10:11:38 AMAFAIL
Phone #: ###-#### Inspection requested via web by daniel bibikov
110.3- Strain relief for sub feed SER at service, clamp shall be snug on SER cable.
110.14- All strands of grounding conductor for range in unit 201 shall terminate in bus bar.
300.4- Where NM cable passes through bored holes that do not maintain 1 1/4" from framing surface they shall be protected from physical damage by nail plates.
408.7- Unused breaker openings shall be closed.
590.6- All temp receptacles shall have GFCI protection. Unable to verify.
ELE15-03575 Temporary Service11/4/201511/5/201511/5/2015 9:24:52 AMAPASS
Phone #: ###-#### Inspection requested via web by daniel bibikov
t/s u/g n ok
ELE15-03514 Electrical Rough-In10/30/201511/5/201511/5/2015 9:08:34 AMANR
We are requesting a rough-in inspection for Thursday Nov. 5th in the AM. Our onsite contact is Bryant @ ###-####. Thank you Phone #: ###-#### Inspection requested via web by Clint Tate Informed wanted inspection 11-6 not today.
ELE15-03011 Final11/4/201511/5/201511/5/2015 8:32:25 AMAPASS
ken Phone #: ###-#### UL listing and disconnecting means confirmed Sign final ok