Inspections for the day of: Monday, November 5, 2018.
Number of inspections: 22
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBen Livingston
TitleMEC-COM/RES INSPECTOR
Phone #576-1208
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-04653 Rough-in11/2/201811/5/201811/5/2018 2:35:45 PMPPASS
Phone #: ###-#### Inspection requested via web by Dan Otero
MEC18-05301 Pressure Test11/5/201811/5/201811/5/2018 2:19:28 PMPPASS
gage at gas meter Phone #: ###-#### Inspection requested via web by anthony allen
20lb
MEC18-05301 Final11/5/201811/5/201811/5/2018 2:19:05 PMPPASS
gage at gas meter Phone #: ###-#### Inspection requested via web by anthony allen
MEC18-00631 Pressure Test11/5/201811/5/201811/5/2018 1:50:03 PMPPASS
if questions call Glen @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann
2nd floor 100lb hydronics from isolation valves x2.
2nd floor gas piping from valve to temp heat and tankless water heater 60lb
MEC18-05278 Pressure Test11/2/201811/5/201811/5/2018 1:27:08 PMPPASS
installer Anas ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
60lb test on low pressure system
MEC18-05202 Pressure Test11/2/201811/5/201811/5/2018 12:54:12 PMPNR
Would like call on way. Thank you Phone #: ###-#### Inspection requested via web by Xanti Berria
MEC18-05202 Rough-in11/2/201811/5/201811/5/2018 12:53:58 PMPNR
Would like call on way. Thank you Phone #: ###-#### Inspection requested via web by Xanti Berria
MEC18-05234 Final10/31/201811/5/201811/5/2018 10:59:19 AMAPASS
Please call Margaret ###-#### on the way Phone #: ###-#### Inspection requested via web by Shauna Llewellyn
MEC18-05277 Rough-in11/2/201811/5/201811/5/2018 10:35:50 AMAPASS
Phone #: ###-#### Inspection requested via web by David Petsche
5lb flue, rough-in
MEC18-03281 Final11/4/201811/5/201811/5/2018 10:12:44 AMAFAIL
Please call Bob before arriving. He will need to give you access. Thank you Phone #: ###-#### Inspection requested via web by Les Gargan
arma flex needs uv protection, range duct needs to be ridged pipe, flex is not approved material
MEC18-02244 Final11/2/201811/5/201811/5/2018 9:46:19 AMAPASS
Phone #: ###-#### Inspection requested via web by Ashley Shoecraft
MEC18-01013 Rough-in11/2/201811/5/201811/5/2018 9:45:30 AMAPASS
Rough in for cover. Call Todd 20 min prior. Phone #: ###-#### Inspection requested via web by Kim Adams
1st floor partial grid ok, 1st floor last room duct seal okay
2nd floor 2 restroom hard lids ok
MEC18-04149 Final11/2/201811/5/201811/5/2018 8:56:05 AMAFAIL
Final on Ductless split install in mother in law suite. Door will be unlocked. Phone #: ###-#### Inspection requested via web by Gary Duncan
armaflex needs uv protection
MEC18-04179 Final11/2/201811/5/201811/5/2018 8:41:42 AMAPASS
JOEY ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza
MEC17-05100 Mec-Aging Inspection11/5/201811/5/201811/5/2018 8:13:16 AM CANC
MEC17-05100 DOC - Permit Expired11/5/201811/5/201811/5/2018 8:13:09 AMPPASS
MEC18-00568 Mec-Aging Inspection11/5/201811/5/201811/5/2018 8:12:42 AM CANC
MEC18-00568 DOC - Permit Expired11/5/201811/5/201811/5/2018 8:12:37 AMPPASS
MEC17-05082 Mec-Aging Inspection11/5/201811/5/201811/5/2018 8:12:05 AM FAIL
MEC18-04913 Final11/2/201811/5/201811/5/2018 8:11:38 AMAPASS
See past inspection results. Electrical permit pulled. Added furnace to our permit. Phone #: ###-#### Inspection requested via web by Arielle Hendricks
MEC18-03281 Final11/4/201811/5/201811/4/2018 5:57:25 PMACANC
Phone #: ###-#### >> Inspection requested via web by Les Gargan Inspection cancelled from web by: Les Gargan
MEC17-05730 Final11/2/201811/5/201811/2/2018 8:23:49 AMACANC
Phone #: ###-#### >> Inspection requested via web by Dawn Kalsbeek Inspection cancelled from web by: Dawn Kalsbeek