Inspections for the day of: Wednesday, November 6, 2002.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorPat Lass
TitleELE-INSPECTOR
Phone #794-9478
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE02-03431 Permanent Service11/5/200211/6/200211/6/2002 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 11/05/2002 at 13:42:00. Contact: ###-####.
ELE02-02259 Final11/5/200211/6/200211/6/2002 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 11/05/2002 at 13:48:56. Contact: ###-####.
6 rooms only 11/6/2002 10:22:43 AM
ELE02-03454 Temporary Service11/5/200211/6/200211/6/2002 12:00:00 AMAFAIL
t/p ron ###-####
408.21 Grounded Conductor Terminations.
Each grounded conductor shall terminate within the panelboard in an individual terminal that is not also used for another conductor.

110.12 Mechanical Execution of Work.
(C) Integrity of Electrical Equipment and Connections. Internal parts of electrical equipment, including busbars, wiring terminals, insulators, and other surfaces, shall not be damaged or contaminated by foreign materials such as paint, plaster, cleaners, abrasives, or corrosive residues.
11/6/2002 8:59:55 AM
ELE01-00309 Electrical Rough-In11/5/200211/6/200211/6/2002 12:00:00 AMAPASS
harold-; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
ELE01-00309 Electrical Rough-In11/5/200211/6/200211/6/2002 12:00:00 AMAPASS
harold-; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
ELE01-03874 Final11/5/200211/6/200211/6/2002 12:00:00 AMAFAIL
fn received card- -scott- ###-####
Mast not supported within 30 in of weatherhead
no access yet to sub panel or inside grounding 11/6/2002 9:55:38 AM
ELE02-02105 Final11/6/200211/6/200211/6/2002 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 11/06/2002 at 06:20:15. Contact: ###-####.
ELE02-03464 Electrical Rough-In11/6/200211/6/200211/6/2002 12:00:00 AMPFAIL
cory- ###-####
300.4 Protection Against Physical Damage.
Where subject to physical damage, conductors shall be adequately protected.
(D) Cables and Raceways Parallel to Framing Members.

314.17 Conductors Entering Boxes, Conduit Bodies, or Fittings.
Conductors entering boxes, conduit bodies, or fittings shall be protected from abrasion and shall comply with 314.17(A) through (D).
(B) Metal Boxes and Conduit Bodies.
…… Where raceway or cable is installed with metal boxes or conduit bodies, the raceway or cable shall be secured to such boxes and conduit bodies.
11/6/2002 1:00:36 PM
ELE02-02149 Electrical Rough-In11/6/200211/6/200211/6/2002 12:00:00 AMPPART
paul--unit 230 & 238; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie 230 & 238 ok 11/6/2002 1:54:34 PM
ELE02-03469 Temporary Service11/6/200211/6/200211/6/2002 12:00:00 AMPPASS
/p ###-####
T/S O/H Ok 11/6/2002 12:38:30 PM
ELE02-03444 Electrical Rough-In11/6/200211/6/200211/6/2002 12:00:00 AMPNR
CONFERENCE ONLY ###-#### TOM PLEASE CALLL 1ST
Had conf 11/6/2002 1:33:53 PM