ELE06-04103
| Electrical Rough-In | 11/6/2006 | 11/6/2006 | 11/6/2006 4:40:41 PM | A | PASS |
|
|
corr made, ric ok
|
ELE06-04103
| Rough-In Permanent Service | 11/4/2006 | 11/6/2006 | 11/6/2006 4:39:32 PM | A | CANC |
|
|
Reinspection. This time please call contact phone number, not office number if there are any problems preventing inspection to pass. Internet Inspection Request from: Latisha Peltier corr made, see ri
|
ELE06-04093
| Electrical Rough-In | 11/6/2006 | 11/6/2006 | 11/6/2006 4:35:08 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 11/6/2006 at 10:11:53 AM. Contact: ###-####. walls only ok to cover
|
ELE06-04122
| Final | 11/6/2006 | 11/6/2006 | 11/6/2006 3:09:18 PM | P | PASS |
|
|
FINAL INSPECTION FOR 220 VOLT SPA CONNECTION. THANKS; Phone #: ###-#### Internet Inspection Request from: Barry Kendall ok to final
|
ELE06-04047
| Electrical Rough-In | 11/6/2006 | 11/6/2006 | 11/6/2006 2:04:51 PM | P | PASS |
|
|
Alan; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt corr made, walls only ok to cover
|
ELE06-04010
| Electrical Rough-In | 11/6/2006 | 11/6/2006 | 11/6/2006 1:10:26 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 11/6/2006 at 10:14:04 AM. Contact: ###-####. walls only ok to cover
|
ELE06-02456
| Final | 11/3/2006 | 11/6/2006 | 11/6/2006 10:39:39 AM | A | NH |
|
|
Phone #: ###-#### Internet Inspection Request from: Therrin Robertson called, code would not work, will have to recall
|
ELE06-04108
| Electrical Rough-In | 11/3/2006 | 11/6/2006 | 11/6/2006 10:22:58 AM | P | CANC |
|
|
Work performed by Ray Hall.; Phone #: ###-#### Internet Inspection Request from: Matt Santacruz wrong type request, see final
|
ELE06-04108
| Final | 11/6/2006 | 11/6/2006 | 11/6/2006 10:22:23 AM | A | PASS |
|
|
Work performed by Ray Hall.; Phone #: ###-#### Internet Inspection Request from: Matt Santacruz ok to final
|
ELE06-02455
| Final | 11/3/2006 | 11/6/2006 | 11/6/2006 9:29:01 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Therrin Robertson called for code, told contr needs faceplate for up bath, ok to final
|
ELE06-03604
| Electrical Rough-In | 11/3/2006 | 11/6/2006 | 11/6/2006 8:24:10 AM | A | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: todd called, left message, left corr notice, nec 358.26 there shall not be over 360 degree bends in emt, 358.30(A) emt shall be securely fastened within 3' of box or termination point, 330.30(B) mc shall be securely supported within 12" of box, 300.4(A)&(D) edge of bored holes and mc cable shall be 1 1/4" from edge of framing members 250.86 all metal boxes shall be grounded
|
ELE06-04082
| Temporary Service | 11/3/2006 | 11/6/2006 | 11/6/2006 8:14:49 AM | A | PASS |
|
|
Re inspect temp pole; Phone #: ###-#### Internet Inspection Request from: todd hall corr made, t/s u/g n ok
|