Inspections for the day of: Tuesday, November 6, 2012.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE10-02837 ELE-Aging Inspection11/6/201211/6/201211/7/2012 2:47:39 PM DONE
still under construction
ELE12-02320 Final11/5/201211/6/201211/6/2012 4:03:25 PMPNH
called, will set up time
ELE12-02606 Electrical Rough-In11/6/201211/6/201211/6/2012 4:02:12 PMPPASS
Please inspect kitchen and living room for cover. Phone #: ###-#### >> Inspection requested via web by ERIC CENTERS ri ok
ELE12-00167 Electrical Rough-In11/6/201211/6/201211/6/2012 4:01:44 PMPCANC
brandon Phone #: ###-#### called, wrong phone number, permit holder did not call
ELE12-02448 Final11/6/201211/6/201211/6/2012 1:19:36 PMPPASS
call prior to going Phone #: ###-#### ok final, signed card
ELE12-02510 Final11/5/201211/6/201211/6/2012 12:36:57 PMPCANC
For entrance to the property please call Jim Fouch at 208 853 5092 Phone #: ###-#### >> Inspection requested via web by John McConnell called, NEC 240, shall mount panel such that breaker handles below 6'-7", NEC 408, complete panel schedule, NEC 250, tie building grounds together, NEC 110 provide work space, NEC 230, shall not have 2 services in building, told contractor to provide drawings and recall for conference or ri
ELE12-02410 Permanent Service11/6/201211/6/201211/6/2012 11:18:20 AMPFAIL
Bob Phone #: ###-#### met owner, shall drive in ground rod at less than 45 degree to vertical, tighten ground clamp, install dead front, roof clearance is ok for service, shall strap feeder conduit to trailer, depth of u/g ok if heaps dirt on top
ELE12-02700 Final11/5/201211/6/201211/6/2012 10:46:16 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Ken Heller ok final
ELE12-01088 Final11/5/201211/6/201211/6/2012 9:47:12 AMAPASS
glenn Phone #: ###-#### ok final
ELE12-02520 Final11/5/201211/6/201211/6/2012 9:14:20 AMAPASS
Office is open after 9:00 am. Thanks Phone #: ###-#### >> Inspection requested via web by Barbara Szurgot ok final, no card
ELE12-02720 Temporary Service11/5/201211/6/201211/6/2012 8:47:03 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Alan Lusk t/s u/g n ok
ELE12-02722 Temporary Service11/5/201211/6/201211/6/2012 8:28:54 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Alan Lusk t/s u/g n ok
ELE12-02721 Rough-In Permanent Service11/5/201211/6/201211/6/2012 8:07:06 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Alan Lusk ri ok, p/s u/g n ok
ELE11-00142 ELE-Aging Inspection11/6/201211/6/201211/6/2012 6:40:43 AM DONE
still under construction, light still same
ELE10-02830 ELE-Aging Inspection11/6/201211/6/201211/6/2012 6:38:52 AM DONE
contractor shall call for final when done, still under construction