Inspections for the day of: Wednesday, November 6, 2013.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-01976 ELE-Aging Inspection11/6/201311/6/201311/7/2013 4:29:27 PM DONE
Waiting on owner
ELE11-01876 ELE-Aging Inspection11/6/201311/6/201311/7/2013 4:21:20 PM DONE
Waiting on owner
ELE13-03108 Conference11/6/201311/6/201311/6/2013 4:42:54 PMPDONE
NICHOLAS PLEASE CALL BEFORE GOING OUT Phone #: ###-#### Discussed counter top recepticals spacing, GFCI protection, required circuits, 1 1/4" rule bored holes and stapling
ELE13-02396 Final11/6/201311/6/201311/6/2013 4:22:42 PMPPASS
KEY IN WHEATHER PROOF AT FRONT DOOR. Phone #: ###-#### >> Inspection requested via web by Bob Glenn Final ok
ELE13-02469 Electrical Rough-In11/6/201311/6/201311/6/2013 3:15:28 PMPPASS
Contact: Wes Powell... Ceiling inspection please Phone #: ###-#### >> Inspection requested via web by Deb Gooden 15th and 16th floor elevator ceiling rough in ok cover
GCE13-00175 GCE-Final11/5/201311/6/201311/6/2013 2:09:28 PMPPASS
Justin ###-#### Sign final ok
ELE13-03110 Temporary Service11/6/201311/6/201311/6/2013 1:31:04 PMPPASS
Phone #: ###-#### >> Inspection requested via web by daniel bibikov t/s u/g n ok
ELE13-03033 Rough-In Permanent Service11/6/201311/6/201311/6/2013 1:29:46 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by daniel bibikov Corrections not complete. 300.4 NM cable shall be protected from physical damage where ran through bored holes and 1 1/4" is not maintained from stud surface. 300.2(C)(1)- All conductors shall have a insulating rating equal to the max voltage in an enclosure.
ELE13-03036 Final11/5/201311/6/201311/6/2013 12:19:31 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Thomas wilson Final ok
ELE13-02580 Final11/6/201311/6/201311/6/2013 10:09:47 AMPPASS
lock box code is 1958 Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman Final ok
ELE13-03097 Temporary Service11/6/201311/6/201311/6/2013 9:56:16 AMPPASS
John Phone #: ###-#### t/s o/h n ok
ELE13-02151 Final11/5/201311/6/201311/6/2013 9:42:02 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Jim Williams Final ok
ELE12-01710 Electrical Rough-In11/5/201311/6/201311/6/2013 9:00:42 AMAPASS
Contact: Wes Powell. ceiling inspection please Phone #: ###-#### >> Inspection requested via web by Deb Gooden 2nd floor ceiling over escalator grid and hard lid rough in ok cover
ELE13-02874 Electrical Rough-In11/1/201311/6/201311/6/2013 12:00:00 AMACANC
Don Phone #: ###-#### 11-6-13 per Donald May cancel this inspection not ready
ELE13-03070 Final11/5/201311/6/201311/5/2013 3:54:03 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by steve ragan
110.14 Dissimilar metals shall not land under same lug. 250.24- Grounding electode conductor shall land at the same lug or terminal as grounded conductor.