Inspections for the day of: Thursday, November 6, 2014.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRex Boyles
TitleELE-INSPECTOR
Phone #685-9023
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-01990 ELE-Aging Inspection11/6/201411/6/201411/7/2014 11:48:10 AM DONE
left message with Tom
ELE14-02698 Final11/6/201411/6/201411/6/2014 4:00:44 PMPPASS
Phone #: ###-#### Inspection requested via web by Stan Woodward final ok
ELE14-02888 Permanent Service11/6/201411/6/201411/6/2014 3:03:36 PMPPASS
we are doing a service change and will need time for Idaho Power to come back and reenter jazz the service please come before 3:30 Phone #: ###-#### Inspection requested via web by Darryn Coburn p/s u/g n ok look for new ground rods before final insp.
ELE14-03111 Electrical Rough-In11/6/201411/6/201411/6/2014 2:44:59 PMPPASS
We Will Be Ready For This Rough In Inspection And I Have Some Questions On The Feeder! Thanks Dave Phone #: ###-#### Inspection requested via web by jason shifflett r/i and u. ground ok existing 2" u.ground confirmed by Dave to be at least 18" from house to shed
ELE14-01124 Final11/5/201411/6/201411/6/2014 2:23:27 PMPFAIL
back slider open. Phone #: ###-#### Inspection requested via web by shane vigil Loose receptacles in kitchen and upst. bath. 406.11-in all areas listed in 210.52 all 125 volt receptacles shall be tamper resistant.ok not to have tamper resistant in area of house not worked on. 314.20-face of box shall be 1/4inch or less to finsh surface(kitchen backsplash) or use box extensions. 210.12(B)-AFCI protection required in all bedrooms. ok not to have afci in old existingbdrms. 210.52(E)(1)-at least one receptacle outlet accessable from grade level required at back of dwelling.ok not to install in front. 210.8(A)(7)- GFCI protection required where receptacles are installed within 6 foot of sink (laundry room). 410.10(A)-recessed fixture in shower not rated for wetlocation.basement bdrm. closet fixture has no globe.
GCE14-00166 GCE-Final11/6/201411/6/201411/6/2014 12:38:55 PMPPASS
Cal ###-#### corrections made final ok
ELE14-02540 Final11/5/201411/6/201411/6/2014 10:15:11 AMAPASS
Robert is the contact Phone #: ###-#### Inspection requested via web by Buster Bowen final ok
ELE14-02000 Final11/5/201411/6/201411/6/2014 10:12:38 AMAPASS
Robert. Phone #: ###-#### Inspection requested via web by Sean DeLacy final ok fitness center
GCE14-00180 GCE-Final11/5/201411/6/201411/6/2014 8:54:41 AMAPASS
Jesse Simpson- ###-####, Please call prior to inspection and He will meet you out there. final ok
GCE14-00182 GCE-Final11/5/201411/6/201411/6/2014 8:53:42 AMAPASS
Jesse Simpson- ###-####, Please call prior to inspection and He will meet you out there. final ok
ELE14-03046 Electrical Rough-In11/5/201411/6/201411/6/2014 8:50:28 AMPCANC
CNBC Smartshop Partial Rough-In. Contact Darby Talbot Phone #: ###-#### >> Inspection requested via web by Tom Betty Inspection cancelled from web by: Tom Betty