ELE11-01990
| ELE-Aging Inspection | 11/6/2014 | 11/6/2014 | 11/7/2014 11:48:10 AM | | DONE |
|
|
left message with Tom
|
ELE14-02698
| Final | 11/6/2014 | 11/6/2014 | 11/6/2014 4:00:44 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Stan Woodward final ok
|
ELE14-02888
| Permanent Service | 11/6/2014 | 11/6/2014 | 11/6/2014 3:03:36 PM | P | PASS |
|
|
we are doing a service change and will need time for Idaho Power to come back and reenter jazz the service please come before 3:30 Phone #: ###-#### Inspection requested via web by Darryn Coburn p/s u/g n ok look for new ground rods before final insp.
|
ELE14-03111
| Electrical Rough-In | 11/6/2014 | 11/6/2014 | 11/6/2014 2:44:59 PM | P | PASS |
|
|
We Will Be Ready For This Rough In Inspection And I Have Some Questions On The Feeder! Thanks Dave Phone #: ###-#### Inspection requested via web by jason shifflett r/i and u. ground ok existing 2" u.ground confirmed by Dave to be at least 18" from house to shed
|
ELE14-01124
| Final | 11/5/2014 | 11/6/2014 | 11/6/2014 2:23:27 PM | P | FAIL |
|
|
back slider open. Phone #: ###-#### Inspection requested via web by shane vigil Loose receptacles in kitchen and upst. bath. 406.11-in all areas listed in 210.52 all 125 volt receptacles shall be tamper resistant.ok not to have tamper resistant in area of house not worked on. 314.20-face of box shall be 1/4inch or less to finsh surface(kitchen backsplash) or use box extensions. 210.12(B)-AFCI protection required in all bedrooms. ok not to have afci in old existingbdrms. 210.52(E)(1)-at least one receptacle outlet accessable from grade level required at back of dwelling.ok not to install in front. 210.8(A)(7)- GFCI protection required where receptacles are installed within 6 foot of sink (laundry room). 410.10(A)-recessed fixture in shower not rated for wetlocation.basement bdrm. closet fixture has no globe.
|
GCE14-00166
| GCE-Final | 11/6/2014 | 11/6/2014 | 11/6/2014 12:38:55 PM | P | PASS |
|
|
Cal ###-#### corrections made final ok
|
ELE14-02540
| Final | 11/5/2014 | 11/6/2014 | 11/6/2014 10:15:11 AM | A | PASS |
|
|
Robert is the contact Phone #: ###-#### Inspection requested via web by Buster Bowen final ok
|
ELE14-02000
| Final | 11/5/2014 | 11/6/2014 | 11/6/2014 10:12:38 AM | A | PASS |
|
|
Robert. Phone #: ###-#### Inspection requested via web by Sean DeLacy final ok fitness center
|
GCE14-00180
| GCE-Final | 11/5/2014 | 11/6/2014 | 11/6/2014 8:54:41 AM | A | PASS |
|
|
Jesse Simpson- ###-####, Please call prior to inspection and He will meet you out there. final ok
|
GCE14-00182
| GCE-Final | 11/5/2014 | 11/6/2014 | 11/6/2014 8:53:42 AM | A | PASS |
|
|
Jesse Simpson- ###-####, Please call prior to inspection and He will meet you out there. final ok
|
ELE14-03046
| Electrical Rough-In | 11/5/2014 | 11/6/2014 | 11/6/2014 8:50:28 AM | P | CANC |
|
|
CNBC Smartshop Partial Rough-In. Contact Darby Talbot Phone #: ###-#### >> Inspection requested via web by Tom Betty Inspection cancelled from web by: Tom Betty
|