Inspections for the day of: Thursday, November 6, 2014.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorCevyn Recla
TitleELE-INSPECTOR
Phone #985-3493
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE10-02651 ELE-Aging Inspection11/6/201411/6/201411/7/2014 9:27:11 AM DONE
Left message
ELE12-01654 ELE-Aging Inspection11/6/201411/6/201411/7/2014 9:19:57 AM DONE
Left message for contractor
ELE14-01597 Electrical Rough-In11/6/201411/6/201411/6/2014 2:37:08 PMPPASS
Partial ceiling, Shane is the contact his cell no. is ###-####. Phone #: ###-#### Inspection requested via web by Shawna Gates
Ceiling OK to cover as noted on prints dated 11-6-14, 16 rooms
ELE14-02797 Final11/6/201411/6/201411/6/2014 1:36:26 PMPPASS
Inspection requested via web by Rowdy Monroe
Final OK
ELE14-02759 Permanent Service11/6/201411/6/201411/6/2014 1:08:20 PMPPASS
PS, OH, N, OK
ELE14-02759 Final11/6/201411/6/201411/6/2014 1:07:30 PMPNR
Matt Phone #: ###-####
Not ready for final, need guy kit, can needs bonded, panel cover missing
ELE14-03104 Final11/5/201411/6/201411/6/2014 12:40:57 PMAPASS
wire ac Phone #: ###-#### Inspection requested via web by PAT MILLER
Final OK
ELE14-03104 Electrical Rough-In11/5/201411/6/201411/6/2014 12:40:35 PMAPASS
wire ac Phone #: ###-#### Inspection requested via web by PAT MILLER
RI OK
ELE14-03107 Electrical Rough-In11/6/201411/6/201411/6/2014 12:26:29 PMAPASS
call 1/2 prior to inspection.
thanks mike
Phone #: ###-#### Inspection requested via web by MIKE HAGERTY
Kitchne, RI OK to cover
ELE14-03043 Electrical Rough-In11/5/201411/6/201411/6/2014 10:22:29 AMACANC
Contact is Alan Krishnek. Phone #: ###-#### Inspection requested via web by Scott Campbell
Bathroom first and second floor, walls ok to cover
ELE14-02551 Final11/4/201411/6/201411/6/2014 9:46:10 AMAFAIL
Access is: Go to the gate on the right side of the residence. There is a keypad. Code is 5285. Return key when finished. Thanks Phone #: ###-#### Inspection requested via web by Paula Gratiot
312.5 B NM cable shall be bushed at opening
225.32 Disconnecting means shall be located at closest point of entrance to seperate building
334.15B Protection of romex -exposed out of framing members in garage
210.8A(5) GFI protection required in unfinished basements
210.52B2 no other receptacle supplied from small appliance circuit, range hood
spoke to contractor
ELE14-02839 Final11/5/201411/6/201411/6/2014 8:47:47 AMAPASS
Phone #: ###-#### Inspection requested via web by Jerry Moore
Final OK