PLM15-02292
| PLM-Aging Inspection | 11/6/2015 | 11/6/2015 | 11/6/2015 3:56:49 PM | | CANC |
|
|
wip
|
PLM15-03821
| Plumbing Rough-in | 11/5/2015 | 11/6/2015 | 11/6/2015 3:48:42 PM | P | FAIL |
|
|
Micah Phone #: ###-#### >change out pvc water 90 to pvc dwv 90 on trap arm. >grade trap arm 1/4" per foot
|
PLM15-03823
| Water and/or Sewer | 11/5/2015 | 11/6/2015 | 11/6/2015 3:14:38 PM | P | PART |
|
|
Onsite Contact is Oliver Granden ###-#### Phone #: ###-#### Inspection requested via web by Eric Bird >visual on sewer @ 9' deep and 2 percent grade ok
|
PLM15-03757
| Plumbing Rough-in | 11/5/2015 | 11/6/2015 | 11/6/2015 2:45:25 PM | P | PASS |
|
|
if questions call Ryan @ ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann
|
PLM15-03794
| Plumbing Rough-in | 11/6/2015 | 11/6/2015 | 11/6/2015 2:21:48 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Aarin Van Curen > mst trap arm backgraded >finish vents and test >vent to be 10 or more from window at mst.
|
PLM15-02568
| Final | 11/6/2015 | 11/6/2015 | 11/6/2015 1:48:41 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by steven smith
|
PLM15-03845
| Water and/or Sewer | 11/6/2015 | 11/6/2015 | 11/6/2015 1:28:34 PM | P | FAIL |
|
|
New main water line install from meter to business. Has new DCBA etc. Ready in PM. Call Joel to confirm. Phone #: ###-#### Inspection requested via web by Scott Sparrell >need to add expansion tank since a DCVA was installed on new water service. >ok to bury
|
PLM15-02676
| Final | 11/6/2015 | 11/6/2015 | 11/6/2015 1:27:21 PM | P | PASS |
|
|
Evan Phone #: ###-####
|
PLM15-03847
| DOC - Permit Finaled | 11/6/2015 | 11/6/2015 | 11/6/2015 12:45:09 PM | P | PASS |
|
|
|
PLM15-03847
| Water and/or Sewer | 11/6/2015 | 11/6/2015 | 11/6/2015 12:44:37 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brett Simmons
|
PLM15-03848
| Water and/or Sewer | 11/6/2015 | 11/6/2015 | 11/6/2015 12:44:34 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brett Simmons
|
PLM15-03848
| DOC - Permit Finaled | 11/6/2015 | 11/6/2015 | 11/6/2015 12:44:31 PM | P | PASS |
|
|
|
PLM15-03719
| Groundwork | 11/6/2015 | 11/6/2015 | 11/6/2015 12:04:06 PM | P | PART |
|
|
DAVID IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER >managers bath ok and trunk line >visual ok on grease line @ FD, pressure test later
|
PLM15-02848
| Final | 11/5/2015 | 11/6/2015 | 11/6/2015 11:38:01 AM | P | PASS |
|
|
18134 Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
|
PLM15-03801
| Final | 11/5/2015 | 11/6/2015 | 11/6/2015 11:23:27 AM | P | PASS |
|
|
Jim Phone #: ###-####
|
PLM15-03569
| Plumbing Rough-in | 11/4/2015 | 11/6/2015 | 11/6/2015 11:10:38 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Tobi Wilson
|
PLM15-03559
| Groundwork | 11/5/2015 | 11/6/2015 | 11/6/2015 11:01:27 AM | A | FAIL |
|
|
if questions call Larry @ ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann >Must have approved plans onsite for inspections.
|
PLM15-02610
| Final | 11/5/2015 | 11/6/2015 | 11/6/2015 10:37:07 AM | A | PASS |
|
|
MIKE IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER >1st floor trim ok
|
PLM15-03844
| Plumbing Rough-in | 11/5/2015 | 11/6/2015 | 11/6/2015 10:05:01 AM | A | PASS |
|
|
IF door is locked go into existing Salon in other building in same parking lot and they will unlock for inspector. Phone #: ###-#### Inspection requested via web by Todd Walter
|
PLM15-01723
| Final | 11/6/2015 | 11/6/2015 | 11/6/2015 9:42:40 AM | A | FAIL |
|
|
3/4 rp in compressor room for all 3 hose bibs Phone #: ###-#### Inspection requested via web by Raul Castanon >rp ok >service sink is s-trapped and bushed down from a 2" trap to a 1.5" trap arm and abs is glued to pvc. repipe sink correctly
|
PLM15-02676
| Final | 11/5/2015 | 11/6/2015 | 11/6/2015 8:44:05 AM | A | FAIL |
|
|
Owner''s phone ###-#### Phone #: ###-#### Inspection requested via web by Evan Royal >need to caulk drinking fountain and breakroom sink.
|
PLM15-03217
| Final | 11/3/2015 | 11/6/2015 | 11/6/2015 7:56:53 AM | A | CANC |
|
|
Anthony Phone #: ###-#### >cancelled per contractor
|
PLM15-03397
| Final | 11/3/2015 | 11/6/2015 | 11/6/2015 12:00:00 AM | P | CANC |
|
|
William Phone #: ###-####
|