Inspections for the day of: Monday, November 6, 2017.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBen Livingston
TitleMEC-COM/RES INSPECTOR
Phone #576-1208
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC17-03087 Final11/6/201711/6/201711/6/2017 3:39:29 PMPPASS
BRECK IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER
MEC17-03812 Final11/3/201711/6/201711/6/2017 3:34:43 PMPNR
Call Eric with any issues @ 412.6613 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek
bvent needs clearence to combustables, water heaters and pool heater still need to be vented,water heaters need to be elivated 18" . need combustion air. gas piping needs to be connected, range hood not installed
MEC17-03300 Final11/6/201711/6/201711/6/2017 3:07:44 PMPPASS
Final inspection ; Eric is your contact Phone #: ###-#### Inspection requested via web by Kim Adams
MEC17-04927 Final11/2/201711/6/201711/6/2017 2:34:47 PMPPASS
customer requested after 2:00 please Phone #: ###-#### Inspection requested via web by Aaron Alandt
MEC17-04887 Rough-in11/3/201711/6/201711/6/2017 1:47:57 PMPPART
Phone #: ###-#### Inspection requested via web by Gary Reeves
5lb flue, rough in pass
MEC17-04887 Pressure Test11/3/201711/6/201711/6/2017 1:47:16 PMPFAIL
Phone #: ###-#### Inspection requested via web by Gary Reeves
no gas pipe
MEC17-03817 Final11/4/201711/6/201711/6/2017 11:09:53 AMAPASS
corrections completed Phone #: ###-#### Inspection requested via web by Krista Boss
MEC17-04888 Rough-in11/3/201711/6/201711/6/2017 10:19:20 AMAFAIL
Phone #: ###-#### Inspection requested via web by Gary Reeves
fans need to be installed, fresh air needs to be 8" to return plenum, not return can
MEC17-04888 Pressure Test11/3/201711/6/201711/6/2017 10:18:10 AMAPASS
Phone #: ###-#### Inspection requested via web by Gary Reeves
20lb gas, 5lb flue
MEC17-03801 Final11/3/201711/6/201711/6/2017 10:17:33 AMAFAIL
garage code 7665 Phone #: ###-#### Inspection requested via web by Andrea Creek
need sediment trap at water heater, armaflex needs uv tape
MEC17-04940 Final11/3/201711/6/201711/6/2017 9:57:55 AMAPASS
Phone #: ###-#### Inspection requested via web by Devony Bullard
MEC17-04283 Final11/3/201711/6/201711/6/2017 9:41:12 AMACANC
MADE CORRECTIONS AND READY FOR FINAL INSPECTION Phone #: ###-#### >> Inspection requested via web by Rick Montgomery Inspection cancelled from web by: Rick Montgomery
MEC17-01938 Conference11/3/201711/6/201711/6/2017 9:24:00 AMAPASS
This is for a duct blast witness Cory will be the tech ###-#### He will be ready around 9AM Inspection requested via web by Konrad Swartz
blast tests x3 passed
MEC17-04958 Pressure Test11/3/201711/6/201711/6/2017 8:51:54 AMAPASS
Tracy Phone #: ###-####
20lb gas
MEC17-04958 Rough-in11/6/201711/6/201711/6/2017 8:51:34 AMAPASS
Tracy Phone #: ###-####
MEC17-04961 Rough-in11/3/201711/6/201711/6/2017 8:50:56 AMAPASS
Kevin Phone #: ###-####
MEC17-01227 Mec-Aging Inspection11/6/201711/6/201711/6/2017 8:11:59 AM PEND
MEC15-00305 Mec-Aging Inspection11/6/201711/6/201711/6/2017 8:10:00 AM PEND
MEC17-03812 Final11/3/201711/6/201711/3/2017 12:46:42 PMACANC
Call Eric with any issues @ 412.6613 Phone #: ###-#### >> Inspection requested via web by Dawn Kalsbeek Inspection cancelled from web by: Dawn Kalsbeek