MEC17-03087
| Final | 11/6/2017 | 11/6/2017 | 11/6/2017 3:39:29 PM | P | PASS |
|
|
BRECK IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER
|
MEC17-03812
| Final | 11/3/2017 | 11/6/2017 | 11/6/2017 3:34:43 PM | P | NR |
|
|
Call Eric with any issues @ 412.6613 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek bvent needs clearence to combustables, water heaters and pool heater still need to be vented,water heaters need to be elivated 18" . need combustion air. gas piping needs to be connected, range hood not installed
|
MEC17-03300
| Final | 11/6/2017 | 11/6/2017 | 11/6/2017 3:07:44 PM | P | PASS |
|
|
Final inspection ; Eric is your contact Phone #: ###-#### Inspection requested via web by Kim Adams
|
MEC17-04927
| Final | 11/2/2017 | 11/6/2017 | 11/6/2017 2:34:47 PM | P | PASS |
|
|
customer requested after 2:00 please Phone #: ###-#### Inspection requested via web by Aaron Alandt
|
MEC17-04887
| Rough-in | 11/3/2017 | 11/6/2017 | 11/6/2017 1:47:57 PM | P | PART |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves 5lb flue, rough in pass
|
MEC17-04887
| Pressure Test | 11/3/2017 | 11/6/2017 | 11/6/2017 1:47:16 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves no gas pipe
|
MEC17-03817
| Final | 11/4/2017 | 11/6/2017 | 11/6/2017 11:09:53 AM | A | PASS |
|
|
corrections completed Phone #: ###-#### Inspection requested via web by Krista Boss
|
MEC17-04888
| Rough-in | 11/3/2017 | 11/6/2017 | 11/6/2017 10:19:20 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves fans need to be installed, fresh air needs to be 8" to return plenum, not return can
|
MEC17-04888
| Pressure Test | 11/3/2017 | 11/6/2017 | 11/6/2017 10:18:10 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves 20lb gas, 5lb flue
|
MEC17-03801
| Final | 11/3/2017 | 11/6/2017 | 11/6/2017 10:17:33 AM | A | FAIL |
|
|
garage code 7665 Phone #: ###-#### Inspection requested via web by Andrea Creek need sediment trap at water heater, armaflex needs uv tape
|
MEC17-04940
| Final | 11/3/2017 | 11/6/2017 | 11/6/2017 9:57:55 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Devony Bullard
|
MEC17-04283
| Final | 11/3/2017 | 11/6/2017 | 11/6/2017 9:41:12 AM | A | CANC |
|
|
MADE CORRECTIONS AND READY FOR FINAL INSPECTION Phone #: ###-#### >> Inspection requested via web by Rick Montgomery Inspection cancelled from web by: Rick Montgomery
|
MEC17-01938
| Conference | 11/3/2017 | 11/6/2017 | 11/6/2017 9:24:00 AM | A | PASS |
|
|
This is for a duct blast witness Cory will be the tech ###-#### He will be ready around 9AM Inspection requested via web by Konrad Swartz blast tests x3 passed
|
MEC17-04958
| Pressure Test | 11/3/2017 | 11/6/2017 | 11/6/2017 8:51:54 AM | A | PASS |
|
|
Tracy Phone #: ###-#### 20lb gas
|
MEC17-04958
| Rough-in | 11/6/2017 | 11/6/2017 | 11/6/2017 8:51:34 AM | A | PASS |
|
|
Tracy Phone #: ###-####
|
MEC17-04961
| Rough-in | 11/3/2017 | 11/6/2017 | 11/6/2017 8:50:56 AM | A | PASS |
|
|
Kevin Phone #: ###-####
|
MEC17-01227
| Mec-Aging Inspection | 11/6/2017 | 11/6/2017 | 11/6/2017 8:11:59 AM | | PEND |
|
|
|
MEC15-00305
| Mec-Aging Inspection | 11/6/2017 | 11/6/2017 | 11/6/2017 8:10:00 AM | | PEND |
|
|
|
MEC17-03812
| Final | 11/3/2017 | 11/6/2017 | 11/3/2017 12:46:42 PM | A | CANC |
|
|
Call Eric with any issues @ 412.6613 Phone #: ###-#### >> Inspection requested via web by Dawn Kalsbeek Inspection cancelled from web by: Dawn Kalsbeek
|