ELE18-03741
| Conference | 11/6/2018 | 11/6/2018 | 11/6/2018 2:14:11 PM | P | DONE |
|
|
This is a project where the customer and I have not been able to agree upon finishing. Rough-in electrical is partially done however I need it inspected so I can walk away. Please call me 1 hour in advance to ensure I can be on site. Phone #: ###-#### Inspection requested via web by Casey Fouts Misc. electrical work done throughout main level, basement and garage. Contractor is going to end his electrical contract. No more work is going to be done at this time. Contractor is going to note areas where work was started and or completed in rough-in areas. During conversation it was mentioned that the property owner needed to hire another licensed electrical contractor to resume electrical work under a new electrical permit.
|
ELE18-03741
| Electrical Rough-In | 11/5/2018 | 11/6/2018 | 11/6/2018 2:11:12 PM | A | CANC |
|
|
This is a project where the customer and I have not been able to agree upon finishing. Rough-in electrical is partially done however I need it inspected so I can walk away. Please call me 1 hour in advance to ensure I can be on site. Phone #: ###-#### Inspection requested via web by Casey Fouts Changed RI inspection to a conference. Contractor to end work with current property owner. During conversation, it was mentioned that the property owner needs to hire another licensed electrical contractor to take over work that has been done.
|
ELE18-03646
| Rough-In Permanent Service | 11/6/2018 | 11/6/2018 | 11/6/2018 12:47:18 PM | P | PASS |
|
|
requesting a cover inspection to proceed also an okay to energize meter please advise have a great Tuesday thankyou for your time Phone #: ###-#### Inspection requested via web by leon ramirez Ok cover. 3 outlets needed, 1 on each wall in foyer(entry) Each wall is 3ft or more in length. 2- D/W's in kitchen need to be hard wired, or outlets moved under sink for them to be readily accessible. Not going to require outlet within 12ft of adjacent outlet on framed in bed upper level as it would be a trip hazard. p/s u/g n ok
|
ELE18-03863
| Electrical Rough-In | 11/5/2018 | 11/6/2018 | 11/6/2018 10:42:07 AM | A | PASS |
|
|
We need a ceiling inspection. Jacob is the site contact. Thank you! Phone #: ###-#### Inspection requested via web by Stacie Tasker Ok cover ceilings in 4 offices S side, and conference rm N side.
|
ELE14-01081
| ELE-Aging Inspection | 11/6/2018 | 11/6/2018 | 11/6/2018 9:33:27 AM | | DONE |
|
|
Please schedule a final inspection.
|
ELE18-03027
| Final | 11/5/2018 | 11/6/2018 | 11/6/2018 9:32:48 AM | A | PASS |
|
|
homeowner will be home. Phone #: ###-#### Inspection requested via web by Calvin Bohrer Of final. GFI recept and floor heat function properly.
|
ELE18-04260
| Electrical Rough-In | 11/5/2018 | 11/6/2018 | 11/6/2018 8:50:50 AM | A | PASS |
|
|
Colin Phone #: ###-####-call when on way Ok cover kitch, bath and bedroom. Homeowners to reside at property.
|
ELE14-01073
| ELE-Aging Inspection | 11/6/2018 | 11/6/2018 | 11/6/2018 5:54:14 AM | | DONE |
|
|
Please coordinate with homeowner and schedule a final inspection.
|