ELE05-02889
| ELE-Aging Inspection | 11/7/2005 | 11/7/2005 | 11/9/2005 3:21:27 PM | | FAIL |
|
|
no name plate
|
ELE05-02890
| ELE-Aging Inspection | 11/7/2005 | 11/7/2005 | 11/8/2005 3:26:57 PM | | PASS |
|
|
|
ELE05-03613
| Electrical Rough-In | 11/7/2005 | 11/7/2005 | 11/7/2005 3:19:33 PM | P | PART |
|
|
loren; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles hard lids ok
|
ELE05-01811
| Rough-In Permanent Service | 11/7/2005 | 11/7/2005 | 11/7/2005 3:09:45 PM | P | PASS |
|
|
mitch -re-insp ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
|
ELE05-01810
| Rough-In Permanent Service | 11/7/2005 | 11/7/2005 | 11/7/2005 3:08:17 PM | P | PASS |
|
|
mitch -re-insp ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
|
ELE05-04029
| Electrical Rough-In | 11/7/2005 | 11/7/2005 | 11/7/2005 3:08:02 PM | P | PASS |
|
|
###-#### - tom
|
MIS05-00205
| ELE-Conference | 11/7/2005 | 11/7/2005 | 11/7/2005 1:58:48 PM | P | FAIL |
|
|
substandard renters complaint -- renter does not have phone so will call to schedule appt. I did not have access to most of the apartment. the service is an older fuse type in fairly good condition. the edison based fuses were all 30 amp so type s fuse adapters shall be installed to prevent overfusing of conductors, also seal unused opening.
|
ELE05-03710
| Final | 11/7/2005 | 11/7/2005 | 11/7/2005 12:52:28 PM | P | PASS |
|
|
bill please call 1/2 hr ; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
ELE05-03966
| Final | 11/4/2005 | 11/7/2005 | 11/7/2005 10:44:46 AM | A | PASS |
|
|
call Chris for access @ 761.9624; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH
|
ELE05-01269
| ELE-Aging Inspection | 11/7/2005 | 11/7/2005 | 11/7/2005 9:26:51 AM | | NR |
|
|
suc
|
ELE05-03288
| Rough-In Permanent Service | 11/4/2005 | 11/7/2005 | 11/7/2005 9:23:21 AM | A | PART |
|
|
Underground inspection ok.; Phone #: ###-#### Internet Inspection Request from: Kathy Briggs
|
ELE05-03597
| Rough-In Permanent Service | 11/4/2005 | 11/7/2005 | 11/7/2005 9:22:41 AM | A | PART |
|
|
Underground inspection ok.; Phone #: ###-#### Internet Inspection Request from: Kathy Briggs
|
ELE05-03587
| Rough-In Permanent Service | 11/4/2005 | 11/7/2005 | 11/7/2005 9:22:18 AM | A | PART |
|
|
Underground inspection ok.; Phone #: ###-#### Internet Inspection Request from: Kathy Briggs
|
ELE05-03239
| Rough-In Permanent Service | 11/4/2005 | 11/7/2005 | 11/7/2005 9:21:52 AM | A | PART |
|
|
Underground inspection ok.; Phone #: ###-#### Internet Inspection Request from: Kathy Briggs
|
ELE05-03872
| Electrical Rough-In | 11/4/2005 | 11/7/2005 | 11/7/2005 9:04:56 AM | A | FAIL |
|
|
cover inspection//jeff; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa kitchen recep on dishwasher dieposal circuit. parallel protection of romex several locations. LB to sub panel undersized add receps. on 2 walls
|
ELE05-01810
| DOC - Permit Finaled | 11/7/2005 | 11/7/2005 | 11/7/2005 12:00:00 AM | P | PASS |
|
|
|
ELE05-01811
| DOC - Permit Finaled | 11/7/2005 | 11/7/2005 | 11/7/2005 12:00:00 AM | P | PASS |
|
|
mitch -re-insp ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
|