ELE05-04037
| Electrical Rough-In | 11/7/2005 | 11/7/2005 | 11/7/2005 5:31:53 PM | P | PASS |
|
|
###-#### - spencer ok cover ri
|
ELE05-03750
| Electrical Rough-In | 11/7/2005 | 11/7/2005 | 11/7/2005 3:33:46 PM | P | PART |
|
|
toby; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok cover ri anop kitchen area walls only
|
ELE05-03995
| Permanent Service | 11/7/2005 | 11/7/2005 | 11/7/2005 3:32:53 PM | P | PASS |
|
|
CONTACT: SHANE KORTE; Phone #: ###-#### Internet Inspection Request from: Deb McCoy p/s o/h reconnect ok
|
ELE05-03996
| Final | 11/7/2005 | 11/7/2005 | 11/7/2005 3:32:17 PM | P | FAIL |
|
|
ray or lana; Phone #: ###-#### Internet Inspection Request from: Barbara Moore corrections nec110.3(b) manufacture requires #6cu for power wire, neurt, wire & ground wire. nec 690.26(B) (5) all metal shall be bonded. B.C.C.4-05-33 emt fittings shall be listed
|
ELE05-01848
| Rough-In Permanent Service | 11/7/2005 | 11/7/2005 | 11/7/2005 3:24:43 PM | P | NR |
|
|
Contact Harvey Reyna.; Phone #: ###-#### Internet Inspection Request from: HARVEY REYNA called t/w harvey he needs to meet with jack regarding this inspections. he okay with that.
|
ELE05-04026
| Electrical Rough-In | 11/6/2005 | 11/7/2005 | 11/7/2005 10:19:38 AM | A | PART |
|
|
common wall with moxie java rough in; Phone #: ###-#### Internet Inspection Request from: Jim Williams ok cover wall between moxie & blimpies only
|
ELE05-03391
| Permanent Service | 11/4/2005 | 11/7/2005 | 11/7/2005 10:15:34 AM | A | PART |
|
|
Contact is Perry. Please arrive 1st thing Monday morning for inspection as we will have Idaho Power on standby for a re-connection once inspection takes place.; Phone #: ###-#### Internet Inspection Request from: David Bonner oked service need to look at all sub panels for seperation ground & neut. 370 oked part ceiling foiled scrim. upstaiirs only p/s u/g reconnect ok
|
ELE05-03758
| Final | 11/3/2005 | 11/7/2005 | 11/7/2005 9:03:35 AM | A | PASS |
|
|
Final the clean room portion of the remodel. ; Phone #: ###-#### Internet Inspection Request from: Del Elwood ok final
|
ELE05-00803
| Final | 11/4/2005 | 11/7/2005 | 11/7/2005 9:00:54 AM | A | PASS |
|
|
supp 02 rkpeterson, Mike need to close this out. Fab tool will see you on Monday. call me when you get onsite. ; Phone #: ###-#### Internet Inspection Request from: Ron Peterson ok final
|
ELE05-03095
| Final | 11/4/2005 | 11/7/2005 | 11/7/2005 9:00:27 AM | A | PASS |
|
|
Supp 02 rkpeterson, this is fab tool in bldg 15 fab 1b to final out. ; Phone #: ###-#### Internet Inspection Request from: Ron Peterson ok final
|
ELE05-03844
| Final | 11/4/2005 | 11/7/2005 | 11/7/2005 9:00:03 AM | A | PASS |
|
|
Supp 02, rkpeterson mike this is a fab tool in FAb 1b bldg 15 Kiyo; Phone #: ###-#### Internet Inspection Request from: Ron Peterson ok final
|
ELE05-03845
| Final | 11/4/2005 | 11/7/2005 | 11/7/2005 8:59:39 AM | A | PASS |
|
|
supp 02 rkpeterson Mike this is a fab tool to final out. thanks; Phone #: ###-#### Internet Inspection Request from: Ron Peterson ok final
|
ELE05-02354
| ELE-Aging Inspection | 11/7/2005 | 11/7/2005 | 11/7/2005 8:58:43 AM | | NR |
|
|
called contractor suc
|
ELE05-03996
| Final | 11/4/2005 | 11/7/2005 | 11/7/2005 8:55:36 AM | A | CANC |
|
|
ray ###-#### wrong address
|
ELE05-04037
| Permanent Service | 11/7/2005 | 11/7/2005 | 11/7/2005 12:00:00 AM | P | PASS |
|
|
###-#### - spencer p/s u/g n ok
|