Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC14-00303 General Inspection11/7/201411/7/201411/7/2014 4:04:57 PM CANC
rescheduled
ESC14-00614 General Inspection11/7/201411/7/201411/7/2014 4:04:05 PM CANC
rescheduled
ESC14-00299 General Inspection11/7/201411/7/201411/7/2014 4:03:25 PM CANC
rescheduled.
ESC14-00310 General Inspection11/7/201411/7/201411/7/2014 4:02:28 PM CANC
rescheduled
ESC14-00326 General Inspection11/7/201411/7/201411/7/2014 4:01:39 PM PASS
ESC14-00296 General Inspection11/7/201411/7/201411/7/2014 4:01:03 PM CANC
rescheduled
ESC14-00342 Aging Inspection11/7/201411/7/201411/7/2014 4:00:17 PM PASS
Earthwork and exterior construction complete. No further ESC inspection required. Permit finaled.
ESC14-00342 DOC - Permit Finaled11/7/201411/7/201411/7/2014 3:59:34 PMPPASS
ESC14-01014 Site Preparation11/7/201411/7/201411/7/2014 3:48:43 PMPPASS
Keath ###-#### @ 3:30

Onsite meeting with RP/GC. Permit to be posted at driveway. There is an ongoing project in front of parcel. No MS4 on Warren, but will need monitor trackout during wet conditions and prevent/clean up as necessary. Lined pit to be used for washout.

Approved for construction.
ESC14-00343 Aging Inspection11/7/201411/7/201411/7/2014 3:27:12 PM PASS
WIP. Work and sediment confined to backyard. No ESC issues.
ESC14-00872 Site Preparation11/7/201411/7/201411/7/2014 3:19:52 PMPPASS
Gordon ###-####

Perimeter wattles installed. Permit posted. Glaztech is supervising the sub-contractors on the job. Low risk site. RP mistakenly filed eNOI but site disturbance is less than 1 acre and is not required.

Approved for warehouse addition construction.
ESC14-00608 Random Inspection11/7/201411/7/201411/7/2014 2:41:01 PMPPART
No effort to sweep up or prevent trackout on Old Hickory. Rest of site is graded so that stormwater is contained by Warm Spring Road embankment. No dewatering at time of inspection. Working an area greater than the listed disturbance. Will continue investigation.

No discharges and Warm Springs is clean and Boise permit posted
ESC13-00755 Random Inspection11/7/201411/7/201411/7/2014 2:38:05 PMPPART
Perimeter BMPs and inlet protection are installed and satisfactory. The interior road is paved but very dirty, with rain the site would discharge muddy stormwater. Site is said to sweep two times daily, but does not appear to be occuring. Unstabilized dirt at east entrance on Lysted is causing trackout and sediment accumulating in gutter.

Need to improve housekeeping and contain the sediment on Lysted street.
ESC13-00684 General Inspection11/7/201411/7/201411/7/2014 2:23:17 PM PASS
Antelope Springs is in good condition. Streets were being cleaned during the inspection, perfect timing. No water flowing through canal at this time, no erosion of sediments from lots, and stormdrains have protection. Site has a permanent contaiment barrier wall. No ESC corrections necessary.
ESC14-00341 Aging Inspection11/7/201411/7/201411/7/2014 2:15:56 PM PASS
Construction of garage complete and all building materials and loose dirt has been removed. ESC permit finaled.
ESC14-00341 DOC - Permit Finaled11/7/201411/7/201411/7/2014 2:15:17 PMPPASS
ESC14-00993 Site Preparation11/7/201411/7/201411/7/2014 2:09:37 PMPPASS
John Phone #: ###-####

Called RP and discussed project and BMPs. Stormdrain is 100 M down the street and very flat. Permit is posted and main BMP will be daily housekeeping as needed. Approved for construction.
ESC14-00630 General Inspection11/7/201411/7/201411/7/2014 1:59:03 PM PASS
Zoo Boise project contained within zoo compound, no issues reported or observed. WIP
ESC14-01048 Site Preparation11/7/201411/7/201411/7/2014 11:51:45 AMPPASS
Jason @ Syman ###-####

All homes to be demolished are surrounded by security fencing. The site is nearly flat, with sheet flow going north in direction of Boise River. Perimeter wattle has been trenched in at the north edge of site and DI on Broadway and Howe has filter protection. Permit posted on K2 sign. Requested that Jason inform K2 to have a water truck on site for dust suppresion during active demolishing.

Approved.
ESC14-00212 BMP Violation11/7/201411/7/201411/7/2014 11:33:58 AMPPASS
Yesterday I requested that RP Jose to re-engineer an improved settling and filtration system before continuing to dewater at Lusk Place. Dewatering was suspended and corrections were made. Jose called at 10:30 AM to inform they rebuilt the system and were getting turbidity measurements well within limits.

The new settling/receiving pond is completely lined with geotextile fabic and has a gravel dam within to increase settling time. After the dam, the water passes through a sediment curtain which was built with the geotextile lining. Before final discharge the water passes through 2 wattles to dissipate the flow. At the hose outlet, filter fabric was wrapped around to form a filter and slow the flow, the hose is layed up plastic piping cut in half to prevent stirriung up sediment under the geotextile fabric. The discharge was visibly clear at end of pond and final outlet and within limits.

Jose will file the corrective action reports in the SWPPP. Corrections complete, site currently in compliance.
ESC14-00743 DOC - Permit Finaled11/7/201411/7/201411/7/2014 10:48:12 AMPPASS
ESC14-00743 Site Final11/7/201411/7/201411/7/2014 10:47:53 AMAPASS
All exterior work complete, home is landscaped and surrounding area free of sediment from construction activities. ESC permit conditions satisfied.
ESC14-00685 Site Final11/6/201411/7/201411/7/2014 10:35:02 AMAPASS
Dan Appel Phone #: ###-#### >> Inspection requested via web by Daniel Appel

House is landscaped and undergoing final cleaning. BLD finaled. ESC conditions satisfied.
ESC14-00685 DOC - Permit Finaled11/7/201411/7/201411/7/2014 10:34:20 AMPPASS
ESC14-00290 Aging Inspection11/7/201411/7/201411/7/2014 10:12:22 AM PASS
Construction complete, yard is landscaped and stabilized. No ESC issues, permit finaled.
ESC14-00290 DOC - Permit Finaled11/7/201411/7/201411/7/2014 10:12:08 AMPPASS
ESC14-00282 General Inspection11/7/201411/7/201411/7/2014 9:55:33 AM PASS
Permit posted, lined concrete washout pit being utilized. No significant trackout or sediment runoff, streets and gutters are clean and all receiving drop inlets have filter bag protection. WIP, no corrections required.
ESC14-00324 General Inspection11/6/201411/7/201411/7/2014 8:48:59 AMPPASS
ESC14-00334 Aging Inspection11/7/201411/7/201411/7/2014 8:40:36 AM PASS
Pool construction and surrounding landscaping complete. ESC permit finaled.
ESC14-00334 DOC - Permit Finaled11/7/201411/7/201411/7/2014 8:40:09 AMPPASS
ESC14-00135 BMP Violation11/4/201411/7/201411/6/2014 12:58:20 PMAPEND
Check for corrections....

Compliance has been extended due to work that is to be completed on the hillside bank in front of house for new utility line installation. Full cleanup and stabilization will be completed after installation of utility line.

No new erosion, trackout, or other issues.