MIS16-00345
| PLM-Conference | 11/1/2016 | 11/1/2016 | | P | |
|
|
|
PLM16-00624
| PLM-Aging Inspection | 11/7/2016 | 11/7/2016 | 11/15/2016 1:00:23 PM | | PEND |
|
|
will schdule
|
PLM16-04051
| Final | 11/7/2016 | 11/7/2016 | 11/7/2016 4:07:30 PM | P | PASS |
|
|
please call homeowner, Grant 45 mins-1 hr prior Phone #: ###-#### Inspection requested via web by Kassy Goodwin. CO detector present.
|
PLM16-03984
| Plumbing Rough-in | 11/7/2016 | 11/7/2016 | 11/7/2016 3:44:41 PM | P | NR |
|
|
Daniel Phone #: ###-####
|
PLM16-03984
| Groundwork | 11/7/2016 | 11/7/2016 | 11/7/2016 3:44:18 PM | P | PASS |
|
|
Daniel Phone #: ###-####
|
PLM16-04043
| Plumbing Rough-in | 11/6/2016 | 11/7/2016 | 11/7/2016 3:16:48 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Branden Steers
|
PLM14-02451
| Final | 11/7/2016 | 11/7/2016 | 11/7/2016 2:05:56 PM | P | FAIL |
|
|
Jalal-please call 15 minutes prior for access Phone #: ###-####. Needs proper backflow devices on the two downstairs hand-held bidet units on the toilets. Recomended vacuum breakers at each bidet.
|
PLM16-04019
| Water Heater Final | 11/3/2016 | 11/7/2016 | 11/7/2016 1:39:30 PM | P | PASS |
|
|
water heater install - customer requests late afternoon inspection. Please call Rick Holland when en route Thank you Phone #: ###-#### Inspection requested via web by JEREMY LINK
|
PLM16-04040
| Groundwork | 11/7/2016 | 11/7/2016 | 11/7/2016 12:31:57 PM | P | PASS |
|
|
|
PLM16-04040
| Plumbing Rough-in | 11/4/2016 | 11/7/2016 | 11/7/2016 12:31:24 PM | P | CANC |
|
|
We are requesting rough-in inspection for bathroom fixtures. Contact Greg Polski : ###-#### Phone #: ###-#### Inspection requested via web by Rusty Karel
|
PLM16-03667
| Plumbing Rough-in | 11/4/2016 | 11/7/2016 | 11/7/2016 10:45:45 AM | A | PASS |
|
|
Please call Todd with an ETA ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann
|
PLM16-03763
| Water and/or Sewer | 11/4/2016 | 11/7/2016 | 11/7/2016 10:19:34 AM | A | FAIL |
|
|
ready for rough in plumbing inspection Phone #: ###-#### Inspection requested via web by Lynn Laurel. 1. pressure test the drainage and vent system. 5#. 2. Install 1-1/2"x5" nail plates. 3. Improper wet vent: Use a 3"x2" santee above the toilet 3" santee. 4. add clean-outs on the 3" drain and the 1-1/2" bar sink drain. Call Dan with any questions: ###-####.
|
PLM16-03340
| Final | 11/7/2016 | 11/7/2016 | 11/7/2016 9:28:46 AM | A | PASS |
|
|
This was a water heater replacement and on the Inspection type was not labeled correctly. Please call if you have any questions Phone #: ###-#### Inspection requested via web by Michael Webb
|
PLM16-04007
| Final | 11/2/2016 | 11/7/2016 | 11/7/2016 9:26:00 AM | A | PASS |
|
|
Please call homeowner, Tom 45 mins-1 hr prior ###-#### Phone #: ###-#### Inspection requested via web by Kassy Goodwin. co alarm installed
|