ELE17-03203
| Electrical Rough-In | 11/7/2017 | 11/7/2017 | 11/7/2017 1:35:28 PM | P | PASS |
|
|
please call ###-#### to make sure I am home. Thanks! Phone #: ###-#### Inspection requested via web by steve keim Basement only rough in ok
|
ELE17-03749
| Rough-In Permanent Service | 11/7/2017 | 11/7/2017 | 11/7/2017 12:39:45 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk rough in ok p/s u/g n ok
|
ELE17-02544
| Final | 11/6/2017 | 11/7/2017 | 11/7/2017 12:13:27 PM | P | FAIL |
|
|
garage code 1524 Phone #: ###-#### Inspection requested via web by Darryn Coburn up NW bedroom dead receps/ Burried recep.
|
ELE17-03166
| Electrical Rough-In | 11/6/2017 | 11/7/2017 | 11/7/2017 11:07:52 AM | A | PASS |
|
|
Call Bryce 1 hour ahead of time Phone #: ###-#### Inspection requested via web by Christian Kilpatrick Listing only ok
|
ELE17-03644
| Electrical Rough-In | 11/6/2017 | 11/7/2017 | 11/7/2017 11:07:30 AM | A | PASS |
|
|
Call Bryce 1 hour ahead of time Phone #: ###-#### Inspection requested via web by Christian Kilpatrick Solar disc rough in only ok
|
ELE17-03644
| Permanent Service | 11/7/2017 | 11/7/2017 | 11/7/2017 11:06:46 AM | P | PASS |
|
|
Call Bryce 1 hour ahead of time Phone #: ###-#### Inspection requested via web by Christian Kilpatrick 250.53G Grounding electrode shall be driven flush with or below ground level. Shall be done before final. p/s u/g rec ok
|
ELE17-03678
| Final | 11/6/2017 | 11/7/2017 | 11/7/2017 10:16:38 AM | A | PART |
|
|
Just an inspection for temporary occupancy. Corbin ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg Construction areas have been partitioned off. No electrical has been checked. Partial final is to occupy existing areas only.
|
ELE17-02378
| Final | 11/3/2017 | 11/7/2017 | 11/7/2017 9:55:01 AM | A | PASS |
|
|
Access code is 7575 or 8080. Phone #: ###-#### Inspection requested via web by Paula Gratiot corrections made final ok
|
ELE17-03666
| Permanent Service | 11/6/2017 | 11/7/2017 | 11/7/2017 8:48:11 AM | A | FAIL |
|
|
Inspection for meter that been without power for more than 1 year Inspection requested via web by steve ragan 250.52A(5) Ground rods shall be 8ft in length (Southern most ground rod has been cut.) 406.9 A and B. receps in damp locations shall have In Use cover. 210.8 B 4. Recerps shall be GFCI protected.
|