Inspections for the day of: Wednesday, November 8, 2006.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-02003 Final11/7/200611/8/200611/9/2006 8:08:29 AMAPART
jared - half of the 4th floor ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith rooms only anop ok to final, south part, no halls
ELE06-04173 Electrical Rough-In11/8/200611/8/200611/8/2006 4:33:34 PMPPASS
Robert ###-#### ric ok in kitchen, told to staple nm cable over panel
ELE06-03378 Final11/7/200611/8/200611/8/2006 4:01:14 PMPCANC
For questions pls call Mike w/Doherty @ ###-####. Scheduled by Heather w/ Doherty; Phone #: ###-#### Internet Inspection Request from: Heather Packer talked to contr, wrong address, no address posted, core and shell not done, fixture missing at entry, said to call when done
ELE06-04073 Permanent Service11/8/200611/8/200611/8/2006 3:17:14 PMPPASS
Work performed by Aaron White.; Phone #: ###-#### Internet Inspection Request from: Matt Santacruz p/s u/g n ok
ELE06-04173 Conference11/8/200611/8/200611/8/2006 3:16:29 PMPDONE
Robert ###-#### //already started work talked about recpts in kitchen
ELE06-03719 Final11/7/200611/8/200611/8/2006 2:34:04 PMPCANC
For questions pls call Mike w/ Doherty @ ###-####. Cover insp. Scheduled by Heather w/Doherty; Phone #: ###-#### Internet Inspection Request from: Heather Packer wrong type insp, see ri
ELE06-03719 Electrical Rough-In11/8/200611/8/200611/8/2006 2:33:31 PMPPASS
For questions pls call Mike w/ Doherty @ ###-####. Cover insp. Scheduled by Heather w/Doherty; Phone #: ###-#### Internet Inspection Request from: Heather Packer ric east walls only ok
ELE06-03264 Electrical Rough-In11/8/200611/8/200611/8/2006 2:01:00 PMPCANC
We have made the corrections you required. ALSO we replaced a pole light on the west end of of the string of power / light poles and re-fed it. Please inspect it also and I will update the Final Job Value to include this work.Thanks !!!! (6080628aaa)Tech/Jason/###-####. ; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell see final, wrong type pequest
ELE06-03264 Final11/8/200611/8/200611/8/2006 2:00:27 PMPPASS
We have made the corrections you required. ALSO we replaced a pole light on the west end of of the string of power / light poles and re-fed it. Please inspect it also and I will update the Final Job Value to include this work.Thanks !!!! (6080628aaa)Tech/Jason/###-####. ; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell corrections made, ok to final
ELE06-03172 Final11/8/200611/8/200611/8/2006 1:33:34 PMPPASS
Internet Inspection Request from: Rowdy Monroe ok to final
ELE06-01852 ELE-Aging Inspection11/8/200611/8/200611/8/2006 1:09:15 PM DONE
suc
ELE06-01805 ELE-Aging Inspection11/8/200611/8/200611/8/2006 1:08:32 PM DONE
suc
ELE06-02206 Electrical Rough-In11/7/200611/8/200611/8/2006 1:02:02 PMAPASS
todd ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ric ok
ELE06-03724 Electrical Rough-In11/7/200611/8/200611/8/2006 9:44:36 AMAFAIL
Billie ###-####//requests around 9am showed owner make-up, 1 1/4", add recpt in bathroom
ELE06-02020 Final11/7/200611/8/200611/8/2006 9:20:23 AMAPASS
Phone #: ###-#### Internet Inspection Request from: ERIC CENTERS called contr to tighten gnd clamps and add screw to box, ok to final, signed occ card
ELE06-01823 Permanent Service11/7/200611/8/200611/8/2006 8:46:41 AMAFAIL
service\final; Phone #: ###-#### Internet Inspection Request from: Rita DeYoung called, left message, left corr notice, nec 110.26(A) shall provide min 30" wide workspace in front of panel
ELE06-04155 Conference11/7/200611/8/200611/8/2006 8:34:21 AMADONE
WE WOULD LIKE TO HAVE YOU LOOK AT THE GROUNDING AND BONDING OF THE SYSTEM DUE TO THE FACT THERE IS A POLY PIPE WATER MAIN IN TO THE BUILDING. KEVIN IS ON-SITE AT ###-####; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH met and discussed service grounding, pvc water incoming, told to drive 2 ground rods
ELE05-00058 Final11/7/200611/8/200611/8/2006 8:25:52 AMACANC
bob ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith talked with contr, will call next week
ELE06-02605 Final11/8/200611/8/200611/8/2006 8:12:07 AMAPASS
Scheduled by a contractor via Hello! on 11/8/2006 at 6:41:39 AM. Contact: ###-####. ok to final
ELE06-03456 Conference11/6/200611/8/200611/7/2006 3:47:36 PMACANC
Phone #: ###-#### Internet Inspection Request from: Patricia Smith Inspection cancelled from web by: Patricia Smith