Inspections for the day of: Wednesday, November 8, 2017.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-03661 Rough-In Permanent Service11/8/201711/8/201711/8/2017 3:42:30 PMPPASS
please call 30-60 min before // Thomas Phone #: ###-####
Check attic for junction boxes for covers. Bath wiring has not been replaced. no 20 amp dedicated.
Kitchen, laundry, beds living rm, rough in ok cover p/s o/h rec ok
ELE16-04017 Electrical Rough-In11/8/201711/8/201711/8/2017 2:55:09 PMPPASS
STR B Landings Phone #: ###-#### Inspection requested via web by Debby Pierce
Rough in for stair B pour rough in ok cover
MIS17-00380 ELE-Conference11/8/201711/8/201711/8/2017 2:06:19 PMPFAIL
Inspecting work for ELE17-03782 and noticed 2 flexible cords had been added to a panel off kitchen. Flexible cords leave panel and are run above grid to location unknown. Jen Davis (Training General manager) ###-#### has been informed of violation and instructed to hire electrical contractor to permit work to replace flexible cords in violation with:
NEC 400.12(1)- Flexible cords shall not be used as a substitute for building wiring.
NEC 400.12 (2)- Flexible cords shall not be run above structural or drop ceilings.
ELE17-03782 Final11/8/201711/8/201711/8/2017 1:53:18 PMPPASS
Inspection for Buffalo Wild Wings power re-routed to HVAC units. Please call prior to arrival for access to kitchen area. Phone #: ###-#### Inspection requested via web by Kevin Perez Final ok
ELE17-03782 Electrical Rough-In11/8/201711/8/201711/8/2017 1:51:05 PMPPASS
Inspection for Buffalo Wild Wings power re-routed to HVAC units. Please call prior to arrival for access to kitchen area. Phone #: ###-#### Inspection requested via web by Kevin Perez
Re-routed power to HVAC units rough in ok
ELE17-02313 Final11/8/201711/8/201711/8/2017 1:20:24 PMPPASS
Phone #: ###-#### Inspection requested via web by Emmet Bushman Final ok
ELE17-02482 Electrical Rough-In11/7/201711/8/201711/8/2017 12:42:27 PMPPASS
Floor heat in 2 bathrooms Insp. Phone #: ###-#### Inspection requested via web by John VanZandt
Upstairs bath and master bath floor heat rough in ok cover
ELE17-02544 Final11/8/201711/8/201711/8/2017 11:35:35 AMPPASS
garage code 1524 Phone #: ###-#### Inspection requested via web by Darryn Coburn
Receptacle located under window behind decorative trim. Large hole cut in trim work to expose receptacle and trimed to drywall at time of final. Final ok
ELE17-03761 Rough-In Permanent Service11/7/201711/8/201711/8/2017 11:11:30 AMACANC
detached garage wiring....thanks!! Phone #: ###-#### Inspection requested via web by Richard Gratiot
Needed rough in only garage fed from house
ELE17-03761 Electrical Rough-In11/8/201711/8/201711/8/2017 11:10:52 AMPPASS
detached garage wiring....thanks!! Phone #: ###-#### Inspection requested via web by Richard Gratiot
Garage panel hot and fed from house. Rough in ok cover
ELE15-04066 Final11/7/201711/8/201711/8/2017 10:19:13 AMAPASS
Aging Phone #: ###-#### Inspection requested via web by Steve VanWinkle
Final ok
ELE15-04066 Electrical Rough-In11/8/201711/8/201711/8/2017 9:48:32 AMPPASS
Aging Phone #: ###-#### Inspection requested via web by Steve VanWinkle
Listing confirmed rough in ok
ELE17-03530 Electrical Rough-In11/7/201711/8/201711/8/2017 9:47:37 AMAPASS
Phone #: ###-#### Inspection requested via web by Mark M
1st floor BMT palliative care grid rough in ok cover
ELE17-03439 Electrical Rough-In11/7/201711/8/201711/8/2017 9:13:11 AMAPASS
Phone #: ###-#### Inspection requested via web by sam petterson
Walls and hardlid rough in ok cover