Inspections for the day of: Thursday, November 9, 2006.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBill VanDegrift
TitlePLM-INSPECTOR
Phone #794-9372
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC06-03636 Conference11/9/200611/9/200611/9/2006 5:26:42 PMPPART
met with keto heating about the combustion air for the 199,900btu instant water heater, the house isnt large enough for all air from inside and the owner didn't want a large hole from outside to the inside. keto wasnt responsible for the combustion air so they wouldnt fire it. told the owner not to fire it if there wasnt combustion air, told plumber the same. he was going to check into a direct vent model.
PLM06-03720 Water and/or Sewer11/7/200611/9/200611/9/2006 4:12:24 PMPPART
after 2:30 air test is at 3:00; Phone #: ###-#### Internet Inspection Request from: Patricia Smith sewer test from mh 2 to mh 5 ok vac test on mh2 and mh5 ok mh3 and mh4 test failed. will review copy of camera when supplied from micron. services not tested
MEC06-00875 Final11/8/200611/9/200611/9/2006 2:06:22 PMANH
Phone #: ###-#### Internet Inspection Request from: Rachael Ingham floors just done
MEC06-02372 Final11/9/200611/9/200611/9/2006 2:03:31 PMPPASS
Internet Inspection Request from: Shelley Baisch
MEC06-03636 Final11/8/200611/9/200611/9/2006 1:48:31 PMPPART
contact person is dave preston, pessure test and final; Phone #: ###-#### Internet Inspection Request from: PATRICK FLEMING 20# test ok needs combustion air prior to final.
MEC06-01873 Pressure Test11/9/200611/9/200611/9/2006 1:32:15 PMPNH
naomi - please call 1/2 hr prior to inspection ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith called no answer, stopped by left notice
MEC06-02754 Rough-in11/9/200611/9/200611/9/2006 12:57:57 PMPPART
On site Cable @ ###-####; J591; Phone #: ###-#### Internet Inspection Request from: Dixie Miyake wall units in 202, 204, 206, 208, AND 210 OK
MEC06-02819 Rough-in11/8/200611/9/200611/9/2006 12:03:32 PMAPASS
Phone #: ###-#### Internet Inspection Request from: Andrea Creek ri ok
MEC06-02819 Pressure Test11/8/200611/9/200611/9/2006 12:03:13 PMAPASS
Phone #: ###-#### Internet Inspection Request from: Andrea Creek 20# test ok
MEC06-03688 Final11/8/200611/9/200611/9/2006 11:36:31 AMAPASS
rick; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
MEC06-03455 Rough-in11/8/200611/9/200611/9/2006 11:24:34 AMAFAIL
mechanical r/i inspection for apartments if you have any question please call me; Phone #: ###-#### Internet Inspection Request from: Calley Shartzer b-vent clearances not per manufacturer, insulate duct ic ceiling 2nd floor end unit, vapor berrier at supply duct takeoffs, needs gas piping installed.
MEC06-03629 Rough-in11/8/200611/9/200611/9/2006 10:25:23 AMAFAIL
les ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith needs osa and exhaust fans per plans, 20#test ok
PLM06-02906 Final11/6/200611/9/200611/9/2006 8:49:50 AMAPASS
Jim; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt