Inspections for the day of: Friday, November 9, 2012.
Number of inspections: 26
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Strole
TitlePLM/MEC-INSPECTOR
Phone #794-7913
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC11-03985 Mec-Aging Inspection11/9/201211/9/201211/13/2012 10:24:31 AM FAIL
left message again
PLM12-02777 Plumbing Rough-in11/8/201211/9/201211/9/2012 3:41:05 PMPFAIL
Dave Phone #: ###-####-cannot vent bathroom with aav and need to vent far right lav per 2003 upc.
PLM12-02763 Final11/8/201211/9/201211/9/2012 2:45:59 PMPPASS
Call RRC Construction for further
information Zak Cell: ###-#### Phone #: ###-#### >> Inspection requested via web by ina schneider-this was just for new fixtures.
PLM12-02763 DOC - Permit Finaled11/9/201211/9/201211/9/2012 2:45:33 PMPPASS
Call RRC Construction for further
information Zak Cell: ###-#### Phone #: ###-#### >> Inspection requested via web by ina schneider-this was just for new fixtures.
MEC12-03116 Final11/9/201211/9/201211/9/2012 2:29:59 PMPNH
Phone #: ###-#### >> Inspection requested via web by Debbie Marino-garage code of lot and block not working. no access, left notice.
MEC12-03999 Pressure Test11/9/201211/9/201211/9/2012 2:11:57 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Raul Castanon-60 lb gas test pass.
MEC12-03998 Pressure Test11/9/201211/9/201211/9/2012 2:10:26 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Raul Castanon-60 lb gas test pass.
MEC12-04000 Pressure Test11/9/201211/9/201211/9/2012 2:09:38 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Raul Castanon-60 lb gas test pass.
PLM12-02793 Water and/or Sewer11/9/201211/9/201211/9/2012 1:57:06 PMPPASS
Brett Phone #: ###-#### >> Inspection requested via web by Brett Simmons
PLM12-02793 DOC - Permit Finaled11/9/201211/9/201211/9/2012 1:56:53 PMPPASS
Brett Phone #: ###-#### >> Inspection requested via web by Brett Simmons
MEC12-03995 Final11/9/201211/9/201211/9/2012 1:45:09 PMPPASS
Please inspect around 1:00pm. Thanks! Phone #: ###-#### >> Inspection requested via web by April Thomas
MEC12-03980 Pressure Test11/8/201211/9/201211/9/2012 1:38:27 PMAPASS
GASPIPER MIGUEL ###-#### CALL MIGUEL FOR PRESSURE TEST Phone #: ###-#### >> Inspection requested via web by Dustin Rich-20 lb gas test pass.
MEC12-03980 Final11/8/201211/9/201211/9/2012 1:35:57 PMPNR
INSTALLER BRIAN ###-#### Phone #: ###-#### >> Inspection requested via web by Dustin Rich
PLM12-02781 Water Heater Final11/8/201211/9/201211/9/2012 1:17:04 PMPPASS
She will be home at one, if you can make it around then. Contact homeowner for access Phone #: ###-#### >> Inspection requested via web by Amanda Drake
MEC12-00661 Mec-Aging Inspection11/9/201211/9/201211/9/2012 12:38:34 PM CANC
MEC12-00656 Final11/8/201211/9/201211/9/2012 10:38:12 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Tom Soniville
PLM12-02782 Water Heater Final11/8/201211/9/201211/9/2012 10:21:12 AMAPASS
Contact Mark for access Phone #: ###-#### >> Inspection requested via web by Amanda Drake
MEC12-03312 Final11/7/201211/9/201211/9/2012 10:06:39 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Carrie Bracamonte
PLM12-02635 Final11/9/201211/9/201211/9/2012 9:48:15 AMPCANC
kelly Phone #: ###-####
PLM12-02753 Water and/or Sewer11/9/201211/9/201211/9/2012 9:47:45 AMAPASS
Phone #: ###-#### >> Inspection requested via web by keith braun
PLM12-02753 DOC - Permit Finaled11/9/201211/9/201211/9/2012 9:47:30 AMPPASS
Phone #: ###-#### >> Inspection requested via web by keith braun
PLM12-02769 Plumbing Rough-in11/8/201211/9/201211/9/2012 9:46:41 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Branden Steers
PLM12-02784 Water and/or Sewer11/8/201211/9/201211/9/2012 9:25:02 AMAPASS
sewer and water Phone #: ###-#### >> Inspection requested via web by Darren Wood
PLM12-02784 DOC - Permit Finaled11/9/201211/9/201211/9/2012 9:24:48 AMPPASS
sewer and water Phone #: ###-#### >> Inspection requested via web by Darren Wood
PLM12-02740 Groundwork11/9/201211/9/201211/9/2012 9:10:13 AMAPASS
will be ready at 930 am, thanks, Boe Phone #: ###-#### >> Inspection requested via web by Boe Jares
MEC12-03827 Rough-in11/9/201211/9/201211/9/2012 8:29:40 AMAFAIL
>> Inspection requested via web by Dustin Rich-20 lb gas test fail, missing transfer grills and need 6" make-up air on the return per the manual-j.