Inspections for the day of: Friday, November 9, 2018.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJames Ady
TitleELE-INSPECTOR
Phone #914-4683
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE18-01206 Electrical Rough-In11/8/201811/9/201811/9/2018 1:55:17 PMPPASS
Please call Bryant for inspection of 1st floor hard lids area C.Thanks. Phone #: ###-#### Inspection requested via web by Rafael Castillo Hard lids on soffit only ok to cover
ELE18-04315 Electrical Rough-In11/9/201811/9/201811/9/2018 12:51:03 PMPPASS
No one will be on site. Front door is unlocked. Homeowner NGC know that you’re coming. Give me a call with any questions. Rough in inspection for kitchen and living room areas. Phone #: ###-#### Inspection requested via web by Garrett Collins Kitchen and living only. ok to cover
ELE18-04293 Permanent Service11/9/201811/9/201811/9/2018 12:07:38 PMPFAIL
Inspection requested via web by Kevin Oderkirk 230.6 Unfused conductors shall be outside the building. 250.66 Grounding electrode system shall be installed
ELE18-04239 Electrical Rough-In11/8/201811/9/201811/9/2018 10:49:17 AMAPASS
Crew Lead Wes Cowan ###-#### Phone #: ###-#### Inspection requested via web by BRS Permitting Listing only ok
ELE18-04287 Final11/8/201811/9/201811/9/2018 10:08:47 AMAPASS
approved plans on site Phone #: ###-#### Inspection requested via web by Ryan King Final ok
ELE18-03554 Final11/7/201811/9/201811/9/2018 10:08:23 AMAFAIL
CALL JAMES WITH QUESTIONS ###-#### Phone #: ###-#### Inspection requested via web by A.M.E. Office Lights missing in hall down hall bath. 210.52C5. Countertop receps shall be within 20in above countertop to be considered work surface recep.. (Rt and Lt of cooktop.
ELE18-03324 Final11/9/201811/9/201811/9/2018 9:59:14 AMAPASS
Call with any questions
Thank you Phone #: ###-#### Inspection requested via web by kim grundhauser final ok
ELE18-03360 Final11/9/201811/9/201811/9/2018 9:07:45 AMAPASS
call with any questions
thank you Phone #: ###-#### Inspection requested via web by kim grundhauser final ok
ELE18-02586 Electrical Rough-In11/8/201811/9/201811/9/2018 8:33:38 AMACANC
Light Poles Please Phone #: ###-#### Inspection requested via web by Winters LLC Pole bases and underground. Back reception wall and restroom wall. One side ONLY for cabinet install. Ok to cover
ELE18-03360 Final11/9/201811/9/201811/9/2018 6:47:54 AMACANC
Call with any questions, and code to get in
Thank you Phone #: ###-#### >> Inspection requested via web by kim grundhauser Inspection cancelled from web by: kim grundhauser
ELE18-03324 Final11/9/201811/9/201811/9/2018 6:46:41 AMACANC
call with any questions, and code to get in
thank you Phone #: ###-#### >> Inspection requested via web by kim grundhauser Inspection cancelled from web by: kim grundhauser