BLD14-01362
| BLD-Final | 11/28/2014 | 12/1/2014 | 12/1/2014 4:00:50 PM | P | NR |
|
|
Late afternoon - Tyler Phone #: ###-####. Fire/life/safety failed.
|
BLD14-03366
| BLD-Final | 12/1/2014 | 12/1/2014 | 12/1/2014 2:21:49 PM | P | PASS |
|
|
20min call before..elise Phone #: ###-####. Ok for perm occ.
|
BLD14-02710
| BLD-Final | 12/1/2014 | 12/1/2014 | 12/1/2014 1:33:44 PM | P | PASS |
|
|
has a fire life safety///John Phone #: ###-####. Pending fire/life/ safety final.
|
BLD14-00209
| BLD-Energy code compliance | 12/1/2014 | 12/1/2014 | 12/1/2014 1:33:08 PM | P | PASS |
|
|
Tyler Phone #: ###-####
|
BLD14-00202
| BLD-Framing/Rough-in | 11/25/2014 | 12/1/2014 | 12/1/2014 10:05:01 AM | A | FAIL |
|
|
Charlie Phone #: ###-####. Roof diaphragm inspection. Edge and field nailing and associated blocking ok. Missing 2 CMSTC40 straps on east and west ends. Also will need engineering on remainder of roof strapping not installed per approved plan. End of straps should have been bent over 2x6 ledger and nailed. In place work, strapping stops at edge of 2x8 and nailed.
|