Inspections for the day of: Monday, December 1, 2014.
Number of inspections: 5
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD14-01362 BLD-Final11/28/201412/1/201412/1/2014 4:00:50 PMPNR
Late afternoon - Tyler Phone #: ###-####. Fire/life/safety failed.
BLD14-03366 BLD-Final12/1/201412/1/201412/1/2014 2:21:49 PMPPASS
20min call before..elise Phone #: ###-####. Ok for perm occ.
BLD14-02710 BLD-Final12/1/201412/1/201412/1/2014 1:33:44 PMPPASS
has a fire life safety///John Phone #: ###-####. Pending fire/life/ safety final.
BLD14-00209 BLD-Energy code compliance12/1/201412/1/201412/1/2014 1:33:08 PMPPASS
Tyler Phone #: ###-####
BLD14-00202 BLD-Framing/Rough-in11/25/201412/1/201412/1/2014 10:05:01 AMAFAIL
Charlie Phone #: ###-####. Roof diaphragm inspection. Edge and field nailing and associated blocking ok. Missing 2 CMSTC40 straps on east and west ends. Also will need engineering on remainder of roof strapping not installed per approved plan. End of straps should have been bent over 2x6 ledger and nailed. In place work, strapping stops at edge of 2x8 and nailed.