BLD15-04472
| BLD-Concrete | 11/30/2016 | 12/1/2016 | 12/1/2016 4:05:09 PM | P | PASS |
|
|
PT deck Phone #: ###-#### Inspection requested via web by Michael West
|
BLD16-03383
| BLD-Framing/Rough-in | 11/30/2016 | 12/1/2016 | 12/1/2016 4:04:57 PM | P | PART |
|
|
Phone #: ###-#### Inspection requested via web by Weston Wagner Transfer point load from girder though the floor and to the foundation, Floor joist hanger in front bedroom and entery need to be replaced and installed correctly 2 of the joist are missing hangers.
|
BLD16-03172
| BLD-Framing/Rough-in | 11/30/2016 | 12/1/2016 | 12/1/2016 4:00:44 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Weston Wagner. Point load support for 2ply girder. OK to insulate
|
BLD16-02844
| BLD-Other | 11/30/2016 | 12/1/2016 | 12/1/2016 3:36:16 PM | P | PART |
|
|
Shear Wall inspection Phone #: ###-#### Inspection requested via web by Shawn Res. Missing hold downs OK to wrap
|
BLD16-03116
| BLD-Foundation | 11/30/2016 | 12/1/2016 | 12/1/2016 1:49:06 PM | P | PASS |
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
|
BLD16-03203
| BLD-Foundation | 11/30/2016 | 12/1/2016 | 12/1/2016 1:48:55 PM | P | PASS |
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
|
BLD16-02070
| BLD-Final | 12/1/2016 | 12/1/2016 | 12/1/2016 1:43:49 PM | P | NR |
|
|
Rolo Phone #: ###-####
|
BLD16-02062
| BLD-Final | 12/1/2016 | 12/1/2016 | 12/1/2016 1:43:28 PM | P | PASS |
|
|
Rolo Phone #: ###-####
|
BLD16-02062
| DOC - Permit Finaled | 12/1/2016 | 12/1/2016 | 12/1/2016 1:43:15 PM | P | PASS |
|
|
|
BLD16-02071
| BLD-Final | 12/1/2016 | 12/1/2016 | 12/1/2016 1:42:23 PM | P | PASS |
|
|
Rolo Phone #: ###-####
|
BLD16-02071
| DOC - Permit Finaled | 12/1/2016 | 12/1/2016 | 12/1/2016 1:42:09 PM | P | PASS |
|
|
|
BLD16-03643
| BLD-Foundation | 12/1/2016 | 12/1/2016 | 12/1/2016 1:25:21 PM | P | PASS |
|
|
doug Phone #: ###-####
|
BLD16-03645
| BLD-Foundation | 12/1/2016 | 12/1/2016 | 12/1/2016 1:25:11 PM | P | PASS |
|
|
doug Phone #: ###-####
|
BLD16-03646
| BLD-Foundation | 12/1/2016 | 12/1/2016 | 12/1/2016 1:24:59 PM | P | PASS |
|
|
doug Phone #: ###-####
|
BLD16-03647
| BLD-Foundation | 12/1/2016 | 12/1/2016 | 12/1/2016 1:24:47 PM | P | PASS |
|
|
doug Phone #: ###-####
|
BLD16-03929
| BLD-Foundation | 11/30/2016 | 12/1/2016 | 12/1/2016 11:05:44 AM | A | PASS |
|
|
Jared Phone #: ###-####
|
BLD16-02590
| BLD-Foundation | 11/30/2016 | 12/1/2016 | 12/1/2016 10:46:08 AM | A | PASS |
|
|
Joe Phone #: ###-####
|
BLD16-00121
| BLD-Energy code compliance | 11/28/2016 | 12/1/2016 | 12/1/2016 10:45:51 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Clint Wall
|