ELE11-02621
| ELE-Aging Inspection | 12/10/2012 | 12/10/2012 | 12/10/2012 3:44:56 PM | | DONE |
|
|
still under construction
|
ELE11-01055
| Final | 12/10/2012 | 12/10/2012 | 12/10/2012 3:43:32 PM | P | PASS |
|
|
ok final
|
ELE11-02586
| Final | 12/10/2012 | 12/10/2012 | 12/10/2012 3:42:40 PM | P | PASS |
|
|
ok final
|
ELE11-01514
| Final | 12/10/2012 | 12/10/2012 | 12/10/2012 2:31:06 PM | P | FAIL |
|
|
Carl Phone #: ###-#### shall add circuit schedules, gfci for outlets out back
|
ELE12-02871
| Electrical Rough-In | 12/10/2012 | 12/10/2012 | 12/10/2012 1:45:57 PM | P | FAIL |
|
|
for mech room and other areas not done at prior rough-in Phone #: ###-#### >> Inspection requested via web by joel smith shall provide 6" free , tighten crimps, add stapling
|
ELE12-02522
| Electrical Rough-In | 12/10/2012 | 12/10/2012 | 12/10/2012 1:09:40 PM | P | PART |
|
|
Please contact Cody for a partial wall cover inspection. Thank you and have a wonderful day! Phone #: ###-#### >> Inspection requested via web by Kevin Perez north end, east and west walls ok, u/g ok if not required to use metal raceway- currently pvc, but may require metal if part of x-ray or patient care area
|
ELE12-02581
| Final | 12/10/2012 | 12/10/2012 | 12/10/2012 12:30:05 PM | P | FAIL |
|
|
>> Inspection requested via web by joel smith left correction notice, NEC 110.22(A) shall identify disconnects, 408.4 shall provide circuit directory, 110.26 shall provide work space about equipment, 314.28A(2) shall provide correct size enclosure used for angle pulls and splices, 230 shall use service rated equipment
|
ELE12-02926
| Permanent Service | 12/7/2012 | 12/10/2012 | 12/10/2012 10:33:40 AM | A | FAIL |
|
|
To get the meters set space A space B Phone #: ###-#### >> Inspection requested via web by Brad Baker called, left message, shall identify service and sub-panels with permanent identification
|
ELE12-02662
| Final | 12/7/2012 | 12/10/2012 | 12/10/2012 10:00:47 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Dan Surerus ok final, signed card
|
ELE12-02540
| Final | 12/7/2012 | 12/10/2012 | 12/10/2012 9:28:06 AM | A | PASS |
|
|
Garage code is JAYO enter Phone #: ###-#### >> Inspection requested via web by Zane Robertson ok final
|
ELE12-02956
| Temporary Service | 12/7/2012 | 12/10/2012 | 12/10/2012 8:57:58 AM | A | PASS |
|
|
Temp Power Phone #: ###-#### >> Inspection requested via web by Zane Robertson t/s u/g n ok
|
ELE12-02958
| Final | 12/7/2012 | 12/10/2012 | 12/10/2012 7:50:23 AM | A | CANC |
|
|
Added Job iD sticker Phone #: ###-#### >> Inspection requested via web by Cevyn Recla see t/s
|
ELE12-02958
| Temporary Service | 12/10/2012 | 12/10/2012 | 12/10/2012 7:50:07 AM | A | PASS |
|
|
Added Job iD sticker Phone #: ###-#### >> Inspection requested via web by Cevyn Recla t/s u/g n ok
|