Inspections for the day of: Wednesday, December 10, 2014.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE14-03219 Electrical Rough-In12/10/201412/10/201412/10/2014 2:15:51 PMPNR
Underslab electrical for x-ray room. We need this inspection to be as late in the day as possible, if that is possible to do. Please call if this cannot be later and we will need to re-schedule for tomorrow. Contact is Justin Bieker. Phone #: ###-#### Inspection requested via web by Richard Montgomery called, left message to call for am inspection
ELE14-03349 Final12/10/201412/10/201412/10/2014 2:14:35 PMPNR
Phone #: ###-#### Inspection requested via web by Bryan Atkins called, asked contractor to finish labelling panel, check for receptacle within 25' of unit since it is roof mounted, check if wiring thru wall was factory supplied
ELE14-03402 Electrical Rough-In12/10/201412/10/201412/10/2014 2:05:26 PMPPASS
Ufer Ground inspection Phone #: ###-#### Inspection requested via web by Celinda Winters ok pour concrete encased electrode
ELE14-03399 Electrical Rough-In12/10/201412/10/201412/10/2014 1:16:02 PMPPASS
underground inspection please Phone #: ###-#### Inspection requested via web by Jay Symonds ok cover u/g house to garage
ELE14-03129 Final12/10/201412/10/201412/10/2014 12:58:54 PMPPASS
Inspection requested via web by Terry Scott ok final
ELE14-03047 Temporary Service12/10/201412/10/201412/10/2014 12:18:11 PMPFAIL
Temporary Power Meter, Contact Shawn Evins @ ###-#### Phone #: ###-#### Inspection requested via web by Tom Betty called, told corrections on-line, shall strap as req'd, label mains and branches, size pull box properly, replace receptacle covers, close openings in j-box, recall when ready
ELE14-01812 Electrical Rough-In12/9/201412/10/201412/10/2014 11:35:24 AMAPASS
Rough-in ceiling soffits in IL building 2nd floor area "A" rooms: A201 ; A202. Call Lonny when on-site. Thanks. Phone #: ###-#### Inspection requested via web by Lonny Baum ok cover soffits as requested
ELE14-02776 Final12/9/201412/10/201412/10/2014 10:56:16 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn ok final
ELE14-02843 Final12/9/201412/10/201412/10/2014 10:36:49 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn ok final
ELE14-03388 Electrical Rough-In12/9/201412/10/201412/10/2014 10:00:10 AMADONE
call on way out.. conference// Kevin Phone #: ###-#### ri ok, talked about taps for service wires into panel
ELE14-03389 Temporary Service12/9/201412/10/201412/10/2014 9:20:24 AMAFAIL
Phone #: ###-#### Inspection requested via web by Kerri Hamilton met electrician, left correction notice, NEC 590.6(B)(1) shall provide gfci protection for cable, 400.5(A) minimum size #4 type so for 60A service, 400.10 shall supply strain relief, 1120.12(A) close unused openings at trailer, 408.4 label circuits, 230.42 shall provide 60A service to trailer, 352.10(F) exposed pvc shall be schedule 80