Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM15-03483 Plumbing Rough-in12/9/201512/10/201512/10/2015 4:27:17 PMPFAIL
Phone #: ###-#### Inspection requested via web by Randy Powell
>DWV test failed on the bath group.
>extend nailplate to corner @ 3" pipe.
>water ok, heat trace must be on a thermostat and not exceed 180 degrees
PLM15-04227 Groundwork12/9/201512/10/201512/10/2015 3:50:00 PMPPASS
lock box 1049 Phone #: ###-#### Inspection requested via web by Craig Johnson
PLM15-04235 Groundwork12/10/201512/10/201512/10/2015 3:17:41 PMPPASS
PLM15-04229 Groundwork12/10/201512/10/201512/10/2015 2:27:59 PMPPASS
Phone #: ###-#### Inspection requested via web by Josh Kelley
PLM15-04230 Groundwork12/10/201512/10/201512/10/2015 2:27:40 PMPPASS
Phone #: ###-#### Inspection requested via web by Josh Kelley
PLM15-04231 Groundwork12/10/201512/10/201512/10/2015 2:27:20 PMPPASS
PLM15-04232 Groundwork12/10/201512/10/201512/10/2015 2:26:36 PMPPASS
PLM15-03935 Plumbing Rough-in12/9/201512/10/201512/10/2015 1:17:56 PMPFAIL
JOB #13509 Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
>water test failed.
PLM15-03792 Final12/10/201512/10/201512/10/2015 11:59:34 AMAPASS
Phone #: ###-#### Inspection requested via web by Roy Towers
PLM15-03979 Plumbing Rough-in12/9/201512/10/201512/10/2015 11:54:47 AMAFAIL
PAUL THOMPSON, SITE MANAGER Phone #: ###-#### Inspection requested via web by Chris Field
1>roll vent on upstairs tub.
2>hang abs every 4' in crawl to end of run.
3>need cleanout at base of stack.
4>tub vented wrong on main level.
5>use a shielded coupling at sewer connection, transition glue not approved for inside the building for pvc to abs.
>6 relocate Hose bibb. not allowed on exterior wall.
PLM15-02691 Final12/9/201512/10/201512/10/2015 11:12:39 AMAFAIL
call ###-#### to make sure unit is open. Phone #: ###-#### Inspection requested via web by Todd Walter
>floor sink cannot be concealed, expose at least half.
>lav sink needs point of use tempering valve per 413.1
PLM15-02365 Groundwork12/9/201512/10/201512/10/2015 10:34:27 AMAPASS
We installed the 90''s as requested. Please look inside tanks to check installation of 90''s. Phone #: ###-#### Inspection requested via web by Brent Lacy
>interceptor 90's ok
PLM15-03423 Final12/9/201512/10/201512/10/2015 9:54:36 AMAPASS
13403 Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
ESC15-01349 BMP Violation12/10/201512/10/201512/10/2015 9:33:59 AMAFAIL
> No filter bag in storm drain on wildwood, mud leaving jobsite on race and entering SD.
>Spoke with Micha, he will have bag installed by the end of the day.
>scheduled an inspection for 12/11 am to check.
PLM15-04223 Water and/or Sewer12/9/201512/10/201512/10/2015 9:24:41 AMAPASS
Phone #: ###-#### Inspection requested via web by Vicki Tallent
>be sure to clean up track out mud at end of day.
PLM15-00110 PLM-Aging Inspection12/10/201512/10/201512/10/2015 8:40:44 AM FAIL
no inspection requested
PLM15-02828 PLM-Aging Inspection12/10/201512/10/201512/10/2015 8:39:35 AM PASS
wip
PLM15-01255 PLM-Aging Inspection12/10/201512/10/201512/10/2015 8:38:49 AM FAIL
no inspection requested
PLM15-04103 Final12/9/201512/10/201512/9/2015 2:37:45 PMAPASS
Please come in before 10am so we can have the trench closed before store opens. Phone #: ###-#### Inspection requested via web by ron pierce
>all ok