PLM15-03483
| Plumbing Rough-in | 12/9/2015 | 12/10/2015 | 12/10/2015 4:27:17 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Randy Powell >DWV test failed on the bath group. >extend nailplate to corner @ 3" pipe. >water ok, heat trace must be on a thermostat and not exceed 180 degrees
|
PLM15-04227
| Groundwork | 12/9/2015 | 12/10/2015 | 12/10/2015 3:50:00 PM | P | PASS |
|
|
lock box 1049 Phone #: ###-#### Inspection requested via web by Craig Johnson
|
PLM15-04235
| Groundwork | 12/10/2015 | 12/10/2015 | 12/10/2015 3:17:41 PM | P | PASS |
|
|
|
PLM15-04229
| Groundwork | 12/10/2015 | 12/10/2015 | 12/10/2015 2:27:59 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Josh Kelley
|
PLM15-04230
| Groundwork | 12/10/2015 | 12/10/2015 | 12/10/2015 2:27:40 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Josh Kelley
|
PLM15-04231
| Groundwork | 12/10/2015 | 12/10/2015 | 12/10/2015 2:27:20 PM | P | PASS |
|
|
|
PLM15-04232
| Groundwork | 12/10/2015 | 12/10/2015 | 12/10/2015 2:26:36 PM | P | PASS |
|
|
|
PLM15-03935
| Plumbing Rough-in | 12/9/2015 | 12/10/2015 | 12/10/2015 1:17:56 PM | P | FAIL |
|
|
JOB #13509 Phone #: ###-#### Inspection requested via web by Ann Marie Reyes >water test failed.
|
PLM15-03792
| Final | 12/10/2015 | 12/10/2015 | 12/10/2015 11:59:34 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Roy Towers
|
PLM15-03979
| Plumbing Rough-in | 12/9/2015 | 12/10/2015 | 12/10/2015 11:54:47 AM | A | FAIL |
|
|
PAUL THOMPSON, SITE MANAGER Phone #: ###-#### Inspection requested via web by Chris Field 1>roll vent on upstairs tub. 2>hang abs every 4' in crawl to end of run. 3>need cleanout at base of stack. 4>tub vented wrong on main level. 5>use a shielded coupling at sewer connection, transition glue not approved for inside the building for pvc to abs. >6 relocate Hose bibb. not allowed on exterior wall.
|
PLM15-02691
| Final | 12/9/2015 | 12/10/2015 | 12/10/2015 11:12:39 AM | A | FAIL |
|
|
call ###-#### to make sure unit is open. Phone #: ###-#### Inspection requested via web by Todd Walter >floor sink cannot be concealed, expose at least half. >lav sink needs point of use tempering valve per 413.1
|
PLM15-02365
| Groundwork | 12/9/2015 | 12/10/2015 | 12/10/2015 10:34:27 AM | A | PASS |
|
|
We installed the 90''s as requested. Please look inside tanks to check installation of 90''s. Phone #: ###-#### Inspection requested via web by Brent Lacy >interceptor 90's ok
|
PLM15-03423
| Final | 12/9/2015 | 12/10/2015 | 12/10/2015 9:54:36 AM | A | PASS |
|
|
13403 Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
|
ESC15-01349
| BMP Violation | 12/10/2015 | 12/10/2015 | 12/10/2015 9:33:59 AM | A | FAIL |
|
|
> No filter bag in storm drain on wildwood, mud leaving jobsite on race and entering SD. >Spoke with Micha, he will have bag installed by the end of the day. >scheduled an inspection for 12/11 am to check.
|
PLM15-04223
| Water and/or Sewer | 12/9/2015 | 12/10/2015 | 12/10/2015 9:24:41 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Vicki Tallent >be sure to clean up track out mud at end of day.
|
PLM15-00110
| PLM-Aging Inspection | 12/10/2015 | 12/10/2015 | 12/10/2015 8:40:44 AM | | FAIL |
|
|
no inspection requested
|
PLM15-02828
| PLM-Aging Inspection | 12/10/2015 | 12/10/2015 | 12/10/2015 8:39:35 AM | | PASS |
|
|
wip
|
PLM15-01255
| PLM-Aging Inspection | 12/10/2015 | 12/10/2015 | 12/10/2015 8:38:49 AM | | FAIL |
|
|
no inspection requested
|
PLM15-04103
| Final | 12/9/2015 | 12/10/2015 | 12/9/2015 2:37:45 PM | A | PASS |
|
|
Please come in before 10am so we can have the trench closed before store opens. Phone #: ###-#### Inspection requested via web by ron pierce >all ok
|