ELE13-01235
| ELE-Aging Inspection | 12/10/2018 | 12/10/2018 | 12/18/2018 12:49:30 PM | | FAIL |
|
|
Called contractor and he said he would check in to job. Drove by did not look like work still going.
|
ELE18-04371
| Final | 12/10/2018 | 12/10/2018 | 12/10/2018 3:12:27 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Barbara Szurgot 210.8- Employee led me to receptacles added. Double duplex to right of counter with sink at right end shall be GFCI protected due to with in 6' of sink.
|
ELE18-04675
| Temporary Service | 12/10/2018 | 12/10/2018 | 12/10/2018 2:48:52 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Neal Rumsey t/s u/g n ok
|
ELE18-04659
| Permanent Service | 12/10/2018 | 12/10/2018 | 12/10/2018 2:31:05 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Trevor Soesbe 200 amp meter main on back of house with sub fed panel in garage, also will be changing most receptacles in house on ungrounded circuits. Late start due to late disconnect of power. At time of inspection meter main with mast in place, and ground rods. Sub feed to panel not in yet or any interior work. p/s o/h rec ok
|
ELE18-03620
| Electrical Rough-In | 12/7/2018 | 12/10/2018 | 12/10/2018 2:06:25 PM | P | PASS |
|
|
Ceiling Inspect please. Phone #: ###-#### Inspection requested via web by CHRIS CARMINE Conference/break room grid rough in ok cover
|
ELE18-02353
| Final | 12/8/2018 | 12/10/2018 | 12/10/2018 2:06:03 PM | P | PASS |
|
|
someone will be home in the afternoon Phone #: ###-#### Inspection requested via web by Charles Davis Master bath light box blanked over tub at time of inspection. Final ok
|
ELE18-04491
| Rough-In Permanent Service | 12/7/2018 | 12/10/2018 | 12/10/2018 1:11:38 PM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn 334.12- NM cable shall not be installed where subject to damage. Garage small bay between garage exterior lights went under truss.
|
ELE18-04654
| Rough-In Permanent Service | 12/6/2018 | 12/10/2018 | 12/10/2018 1:11:04 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kevin Heideman Rough in ok cover p/s u/g n ok
|
ELE18-04670
| Temporary Service | 12/7/2018 | 12/10/2018 | 12/10/2018 10:05:01 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by cal crosby t/s u/g n ok
|
ELE18-04007
| Final | 12/4/2018 | 12/10/2018 | 12/10/2018 9:20:39 AM | A | FAIL |
|
|
Garage Code 2468 Phone #: ###-#### Inspection requested via web by Icon Electric 210.12- All outlets in a bedroom shall have AFCI protection with the AFCI device installed at circuits origin. Up bed.
|