MEC17-03751
| Pressure Test | 12/10/2018 | 12/10/2018 | 12/10/2018 3:55:36 PM | P | PASS |
|
|
gas test- 60lb gas pass whole system
|
MEC18-05899
| Final | 12/10/2018 | 12/10/2018 | 12/10/2018 3:20:44 PM | P | PASS |
|
|
Please call Tony at ###-#### 1 hour prior to arrival. They should be done around 2pm. Phone #: ###-#### Inspection requested via web by kelly Martin- furnace co ok
|
MEC18-05879
| Rough-in | 12/7/2018 | 12/10/2018 | 12/10/2018 2:29:16 PM | P | FAIL |
|
|
code 2468 Phone #: ###-#### Inspection requested via web by Randy Hart- gauge on gas wont zero out- need to seal exhaust fans to metal 90s on all fans underneath flex- need to seal all boots to floor and seal inside of boots-need to fix all rips and tears in arma flex by final- range duct needs to be smooth walled, remove oval 90 degree and reroute omitting 90 and oval to round reducer- dryer vent needs a termination box installed and seal behind tub so no dry wall will be installed on other side- need to cancel/reschedule duct blast test til after all corrections are made thats on for tomorrow in morning and give one day notice for airbalance test- left correction notice front entry window
|
MEC18-05879
| Pressure Test | 12/7/2018 | 12/10/2018 | 12/10/2018 2:22:34 PM | P | FAIL |
|
|
code 2468 Phone #: ###-#### Inspection requested via web by Randy Hart- gauge wont zero out
|
MEC18-05895
| Rough-in | 12/7/2018 | 12/10/2018 | 12/10/2018 1:40:41 PM | P | PART |
|
|
Partial R/I Phone #: ###-#### Inspection requested via web by Bryan Palmer- need approved stamped manual J onsite for next inspection- this was to just get heat back on with new furnace location
|
MEC18-05895
| Pressure Test | 12/7/2018 | 12/10/2018 | 12/10/2018 1:40:41 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bryan Palmer- 20lb gas pass to furnace- 5lb flue pass
|
MEC18-05892
| Pressure Test | 12/7/2018 | 12/10/2018 | 12/10/2018 11:21:19 AM | A | PART |
|
|
Please call owner 1 hour prior to arrival. Paul Nelson Phone #: ###-#### Inspection requested via web by Jamee Shoecraft- 20lb gas pass to fireplace location- csst gas piping needs protective sleeve thru concrete per manufactures installation instructions
|
MEC18-05885
| Pressure Test | 12/7/2018 | 12/10/2018 | 12/10/2018 10:21:25 AM | A | FAIL |
|
|
Thanks! Inspection requested via web by Floyd Floyd Peek- gauge wont zero out- 10mil inert tape needs to be sealed to pipe to protect fittings has gaps- seal completely- recall in when corrections are made
|
MEC18-05845
| Final | 12/6/2018 | 12/10/2018 | 12/10/2018 10:11:23 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette- need to insulate bare metal on R/A plenum and fitler box excluding access door
|
MEC18-05860
| Final | 12/6/2018 | 12/10/2018 | 12/10/2018 9:46:51 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kim Lithander- furnace a/c co ok
|
MEC18-05720
| Final | 12/6/2018 | 12/10/2018 | 12/10/2018 9:16:36 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Marisa Hone- furnace a/c coil co ok
|
MEC18-05407
| Final | 12/7/2018 | 12/10/2018 | 12/10/2018 8:43:43 AM | A | NH |
|
|
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN- no one home- no access
|
MEC17-02909
| Mec-Aging Inspection | 12/10/2018 | 12/10/2018 | 12/10/2018 8:29:56 AM | | CANC |
|
|
|
MEC17-02909
| DOC - Permit Expired | 12/10/2018 | 12/10/2018 | 12/10/2018 8:29:46 AM | A | PASS |
|
|
no calls
|