Inspections for the day of: Tuesday, December 10, 2019.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMark Moncarr
TitleELE-INSPECTOR
Phone #685-9023
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-03396 Final12/9/201912/10/201912/10/2019 2:18:20 PMPPASS
Phone #: ###-#### Inspection requested via web by Rodney Monroe Ok final.
ELE19-01497 Final12/9/201912/10/201912/10/2019 2:17:55 PMPPASS
Phone #: ###-#### Inspection requested via web by Rodney Monroe Ok final.
ELE19-04672 Final12/10/201912/10/201912/10/2019 1:43:11 PMPNR
Justin Metcalf ###-#### or Corbin Metcalf ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg
ELE19-04314 Electrical Rough-In12/10/201912/10/201912/10/2019 12:38:18 PMPPASS
Please call Shaun at ###-#### before arriving on site, so that we can have someone meet the inspector. Thanks! Phone #: ###-#### Inspection requested via web by Jesse Simpson Ok cover. Components UL listed
ELE19-04398 Electrical Rough-In12/9/201912/10/201912/10/2019 11:11:46 AMAPASS
You can also contact Shea Rodgers ###-#### for access to house. There is also a lock box on the back side entrance to the house. Lock box code is 0275 Phone #: ###-#### Inspection requested via web by Noah Giver Ok cover up bath, bed, kitch and laundry
ELE19-04233 Electrical Rough-In12/9/201912/10/201912/10/2019 11:11:14 AMAPASS
Ceiling grid Phone #: ###-#### Inspection requested via web by Jim Williams Ok cover ceilings
ELE19-04250 Final12/10/201912/10/201912/10/2019 10:56:14 AMPFAIL
Jay Phone #: ###-####
1. Both AC's max fuse is 15. 2 pole 30's installed.
2. Mstr recept by toilet needs GFI protected.
3. AC disconnects need labled to match panel.
4. 1 AC disc and hot tub disc need secured. Both not attached very well.
5. Space 6 in up panel needs labeled.
ELE19-03434 Electrical Rough-In12/10/201912/10/201912/10/2019 10:06:36 AMAPASS
We Would Like To Get A Partial Room Inspection And The Exterior Soffits For Cover Rough In. Thanks So Much We Will Be All Ready For Ya! Phone #: ###-#### Inspection requested via web by jason shifflett Ok cover 4 offices and hall S side.
ELE19-04714 Electrical Rough-In12/9/201912/10/201912/10/2019 10:06:03 AMAPASS
Walls only. Unit is vacant and will be open for inspection. Any questions call Josh Smith.
Phone #: ###-#### Inspection requested via web by Candy Magly Ok cover walls in 2 rooms suite 205.
ELE19-03311 Electrical Rough-In12/9/201912/10/201912/10/2019 9:12:05 AMAPASS
inspection for floor heat in both the master bathroom and basement bathroom Phone #: ###-#### Inspection requested via web by Bonnie Page Ok cover flr heat mstr and basement.
ELE19-04451 Electrical Rough-In12/9/201912/10/201912/10/2019 8:36:02 AMACANC
Please call Brian Prussia with any questions or concerns at ###-#### Phone #: ###-#### Inspection requested via web by BRS Permitting Rescheduled for 12/11. Materials will be on site then. Will do RI and final.