MEC19-05515
| Rough-in | 12/10/2019 | 12/10/2019 | 12/10/2019 4:01:33 PM | P | PASS |
|
|
Phone #: 2088718789 >> Inspection requested via mobile web by Albert - R/I ok
|
MEC19-05515
| Pressure Test | 12/10/2019 | 12/10/2019 | 12/10/2019 4:01:19 PM | P | PASS |
|
|
Phone #: 2088718789 >> Inspection requested via mobile web by Albert - 20lb gas pressure test ok
|
MEC19-05538
| Final | 12/9/2019 | 12/10/2019 | 12/10/2019 3:53:01 PM | P | PASS |
|
|
INSTALLER TRAVIS ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt - unit 201 furnace only co ok
|
MEC19-05557
| Rough-in | 12/10/2019 | 12/10/2019 | 12/10/2019 3:26:10 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Joe Taylor -condensate line needs to be 3/4" min and of approved material - only use condensate pump to achieve grade
|
MEC19-05227
| Final | 12/5/2019 | 12/10/2019 | 12/10/2019 3:16:11 PM | P | PASS |
|
|
Homeowner Kurt Atkins ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
|
MEC19-05500
| Final | 12/6/2019 | 12/10/2019 | 12/10/2019 2:43:30 PM | P | FAIL |
|
|
Client is available from 12-4pm on Tuesday. JuLee is contact. Phone #: ###-#### Inspection requested via web by Andrea Grigsby - furnace flue needs b vent through ceiling and roof replaced and extended through roof and terminate with listed cap/ roof assembly to proper height based on roof slope
|
MEC19-05560
| Final | 12/10/2019 | 12/10/2019 | 12/10/2019 1:50:52 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by max sanders - final ok
|
MEC19-05560
| Pressure Test | 12/10/2019 | 12/10/2019 | 12/10/2019 1:50:40 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by max sanders - 20lb gas pressure test ok
|
MEC19-05541
| Pressure Test | 12/9/2019 | 12/10/2019 | 12/10/2019 1:13:17 PM | P | FAIL |
|
|
Please call Dan on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks - gauge would not zero
|
MEC19-05541
| Final | 12/9/2019 | 12/10/2019 | 12/10/2019 1:12:43 PM | P | CANC |
|
|
Please call Dan on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
|
MEC19-05089
| Final | 12/5/2019 | 12/10/2019 | 12/10/2019 12:52:07 PM | P | CANC |
|
|
Homeowner Jon Corlett ###-#### Phone #: ###-#### >> Inspection requested via web by Mary LaFayette Inspection cancelled from web by: Mary LaFayette
|
MEC19-05486
| Final | 12/9/2019 | 12/10/2019 | 12/10/2019 11:20:33 AM | A | PASS |
|
|
Inspection requested via web by Jeff Glynn
|
MEC19-05196
| Rough-in | 12/9/2019 | 12/10/2019 | 12/10/2019 11:04:30 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Benny Arreola - need to access to furnace and equipment in attic - man J approved and onsite - CSST near range needs full strikers plates installed in wall studs - where is mechanically vented crawls intake coming from within the house?
|
MEC19-05196
| Pressure Test | 12/9/2019 | 12/10/2019 | 12/10/2019 11:01:29 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Benny Arreola - gas pressure test needs to be a 60lb test on a 100lb
|
MEC19-05152
| Final | 12/9/2019 | 12/10/2019 | 12/10/2019 10:29:02 AM | A | FAIL |
|
|
call for lock box code // Santiago Phone #: ###-#### - furnace needs electrical wiring finished - dryer vent needs finished - furnace flue and all work in attic has not been inspected. need access
|
MEC19-05152
| Pressure Test | 12/9/2019 | 12/10/2019 | 12/10/2019 10:24:27 AM | A | PASS |
|
|
call for lock box code // Santiago Phone #: ###-#### - 20lb gas pressure test ok
|
MEC19-05350
| Final | 12/9/2019 | 12/10/2019 | 12/10/2019 10:08:43 AM | A | FAIL |
|
|
Our Salesman will meet the inspector at the location. We are just down the road from location please call ahead or when arrived and will have the salesman there. Thank you Phone #: ###-#### Inspection requested via web by Loren Bailey - line set in attic needs insulation filled in and fixed - secondary drain needs a wet switch - line set needs UV protection and locking caps installed on three service ports
|
MEC19-02174
| Mec-Aging Inspection | 12/10/2019 | 12/10/2019 | 12/10/2019 8:02:07 AM | | FAIL |
|
|
Permit has not been active since being issued on 5-23-19. Schedule inspection with homeowner if work is finished. Permit will expire at next mechanical aging inspection if not active.
|
MEC19-02173
| Mec-Aging Inspection | 12/10/2019 | 12/10/2019 | 12/10/2019 8:00:07 AM | | FAIL |
|
|
Permit has not been active since being issued on 5-23-19. Schedule inspection with homeowner if work is finished. Permit will expire at next mechanical aging inspection if not active.
|
MEC18-02236
| Mec-Aging Inspection | 12/10/2019 | 12/10/2019 | 12/10/2019 7:58:37 AM | | FAIL |
|
|
Permit has not been active since talking with the contractor. Type1 hood still has corrections that need made. Schedule inspection if corrections have been made. Permit will expired at next mechanical aging inspection if not active.
|