ELE08-02509
| ELE-Aging Inspection | 12/11/2008 | 12/11/2008 | 12/19/2008 11:35:47 AM | | PASS |
|
|
|
ELE08-03201
| Final | 12/11/2008 | 12/11/2008 | 12/11/2008 4:06:19 PM | P | PASS |
|
|
greg Phone #: ###-####
|
ELE08-01186
| Permanent Service | 12/11/2008 | 12/11/2008 | 12/11/2008 3:54:36 PM | P | FAIL |
|
|
daniel Phone #: ###-#### no main bonding jumpers, breakers too high, equipment ground not run with feed to panel, grounding electrode conductors not to be spliced in panel buss. modified cable connector used as chase niple, cable to follow surface closely in unfinished basement isolate neutrals in sub panel one sub panel too high to remove cover. ground metal boxes, 4 wire receptacle to be fed with 4 wires.
|
ELE08-01186
| Electrical Rough-In | 12/11/2008 | 12/11/2008 | 12/11/2008 3:09:23 PM | P | PART |
|
|
daniel Phone #: ###-#### main level ok
|
ESC08-00623
| General Inspection | 12/11/2008 | 12/11/2008 | 12/11/2008 2:04:51 PM | P | PASS |
|
|
looks ok
|
ELE08-03211
| Electrical Rough-In | 12/11/2008 | 12/11/2008 | 12/11/2008 2:04:34 PM | P | PASS |
|
|
Call 30 mins prior to going for access Phone #: ###-####
|
ESC08-00845
| General Inspection | 12/11/2008 | 12/11/2008 | 12/11/2008 1:39:38 PM | P | PASS |
|
|
looks ok
|
ELE08-03139
| Final | 12/11/2008 | 12/11/2008 | 12/11/2008 1:25:45 PM | P | PASS |
|
|
sam Phone #: ###-####
|
ESC08-00619
| General Inspection | 12/11/2008 | 12/11/2008 | 12/11/2008 11:43:16 AM | A | PASS |
|
|
looks ok
|
ESC08-00851
| General Inspection | 12/11/2008 | 12/11/2008 | 12/11/2008 11:42:56 AM | A | CANC |
|
|
|
ELE08-01996
| Electrical Rough-In | 12/10/2008 | 12/11/2008 | 12/11/2008 11:42:25 AM | A | PASS |
|
|
arvella - please call 15 min prior Phone #: ###-####
|
ELE08-02246
| Final | 12/10/2008 | 12/11/2008 | 12/11/2008 10:18:41 AM | A | PASS |
|
|
contact: Bob Schroder **** Go through side gate, side garage door will be open.**** Phone #: ###-#### Internet Inspection Request from: Julie Schroder
|
ESC08-00659
| General Inspection | 12/11/2008 | 12/11/2008 | 12/11/2008 10:18:24 AM | A | PASS |
|
|
looks ok
|
ELE08-03017
| Final | 12/10/2008 | 12/11/2008 | 12/11/2008 10:04:43 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Kerri Hamilton
|
ELE08-01919
| Final | 12/11/2008 | 12/11/2008 | 12/11/2008 9:48:30 AM | A | NH |
|
|
Phone #: ###-#### Internet Inspection Request from: Brandon Blackham will rechedual when ceiling is open ond someone on site.
|
ESC05-00363
| General Inspection | 12/11/2008 | 12/11/2008 | 12/11/2008 8:50:49 AM | A | PASS |
|
|
looks ok
|
ELE08-03200
| Electrical Rough-In | 12/10/2008 | 12/11/2008 | 12/11/2008 8:50:30 AM | A | FAIL |
|
|
Try to do first thing. Todd-please call if have any questions about inspection so he can explain to you what is going on. Phone #: ###-#### replace damaged mc cable
|