ELE09-02381
| Electrical Rough-In | 12/11/2009 | 12/11/2009 | 12/11/2009 2:16:32 PM | P | PASS |
|
|
THEY ADDED A FLOOR OUTLET IN THE LIVING ROOM Phone #: ###-#### Internet Inspection Request from: Bob Glenn ok to cover floor box
|
ESC09-00731
| General Inspection | 12/11/2009 | 12/11/2009 | 12/11/2009 2:12:06 PM | P | PASS |
|
|
looked ok
|
ELE09-02194
| Final | 12/11/2009 | 12/11/2009 | 12/11/2009 2:11:21 PM | P | PASS |
|
|
Darrin-1234 code Phone #: ###-#### ok to final, called contractor
|
ESC09-00613
| General Inspection | 12/11/2009 | 12/11/2009 | 12/11/2009 2:10:00 PM | P | PASS |
|
|
looked ok
|
ESC09-00350
| General Inspection | 12/11/2009 | 12/11/2009 | 12/11/2009 1:40:11 PM | P | PASS |
|
|
looked ok
|
ESC09-00723
| General Inspection | 12/11/2009 | 12/11/2009 | 12/11/2009 1:39:14 PM | P | PASS |
|
|
looked ok
|
ESC09-00588
| General Inspection | 12/11/2009 | 12/11/2009 | 12/11/2009 1:32:53 PM | P | PASS |
|
|
looked ok
|
ESC09-00181
| General Inspection | 12/11/2009 | 12/11/2009 | 12/11/2009 1:19:19 PM | P | PASS |
|
|
looked ok
|
ELE09-02361
| Permanent Service | 12/11/2009 | 12/11/2009 | 12/11/2009 12:36:06 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: cory carman p/s o/h rec ok, no esc this project
|
ELE09-02391
| Permanent Service | 12/11/2009 | 12/11/2009 | 12/11/2009 11:49:00 AM | P | PASS |
|
|
Dan Phone #: ###-####- call prior to going to meet p/s u/g rec ok, no esc this project
|
ELE09-01932
| Electrical Rough-In | 12/10/2009 | 12/11/2009 | 12/11/2009 10:59:27 AM | A | PART |
|
|
Nick is the onsite contact, his cell no. is ###-####. Phone #: ###-#### Internet Inspection Request from: Shawna Gates walls for phase 6 anop ok to cover, left correction notice for phase 5 and 6-NEC 300.11 raceways, boxes, and cable assemblies shall be securely fastened in place. Support wires shall be secured at both ends. 362.30(A) ent shall be secured within 3' of box and every 3'. BCC no violations shall be retained
|
ELE09-02390
| Final | 12/10/2009 | 12/11/2009 | 12/11/2009 10:01:07 AM | A | PASS |
|
|
Rick, optional number Steve @ ###-#### Phone #: ###-#### Internet Inspection Request from: Rick Beckman ok to final, no esc this project
|
ELE09-02390
| Electrical Rough-In | 12/11/2009 | 12/11/2009 | 12/11/2009 10:00:15 AM | A | PASS |
|
|
Rick, optional number Steve @ ###-#### Phone #: ###-#### Internet Inspection Request from: Rick Beckman ri ok, no esc this project
|
ELE09-02232
| Electrical Rough-In | 12/10/2009 | 12/11/2009 | 12/11/2009 9:56:10 AM | A | PASS |
|
|
COVER INSPECTION FOR ADDITION - ELECTRICIAN LUKE ###-#### Phone #: ###-#### Internet Inspection Request from: Dave Koeppen ric ok
|
ELE09-02103
| Electrical Rough-In | 12/11/2009 | 12/11/2009 | 12/11/2009 9:23:58 AM | P | PART |
|
|
cvr wall from yesterday Phone #: ###-#### Internet Inspection Request from: dennis mcneely ok to cover with mud master bedroom and dining room walls only
|
ELE09-01826
| Final | 12/10/2009 | 12/11/2009 | 12/11/2009 8:38:22 AM | A | PART |
|
|
Phone #: ###-#### Internet Inspection Request from: Scott Campbell part final ok, called contractror to tighten receptacles, provide gfci for drinking fountains and refrigerator, signed t/o card
|
ELE09-02385
| Permanent Service | 12/10/2009 | 12/11/2009 | 12/11/2009 7:33:01 AM | A | CANC |
|
|
Late morning would be appreciated. Phone #: ###-#### Internet Inspection Request from: John McCurdy Inspection cancelled from web by: John McCurdy
|