ELE17-03390
| Final | 12/11/2017 | 12/11/2017 | 12/11/2017 2:39:58 PM | P | FAIL |
|
|
Mitch Phone #: ###-#### 110.3- GFCI in garage opposite wall from panel shows open ground. 110.27- All wiring in unfinished garage walls located below 8' shall be protected from physical damage. Ceiling not 8' so cover wiring up to ceiling in stud bays where exposed. 210.8- GFCI devices shall be located in a readily accessible areas. Eave receptacle located above 6'7".
|
ELE17-03410
| Final | 12/11/2017 | 12/11/2017 | 12/11/2017 2:03:08 PM | P | PASS |
|
|
Garage code 1001E Phone #: ###-#### Inspection requested via web by Alan Lusk Final ok
|
ELE17-03012
| Final | 12/9/2017 | 12/11/2017 | 12/11/2017 1:20:34 PM | A | PASS |
|
|
Dispenser and tank monitor wiring. Phone #: ###-#### Inspection requested via web by Paul White Final ok
|
ELE17-03012
| Electrical Rough-In | 12/11/2017 | 12/11/2017 | 12/11/2017 1:19:34 PM | P | PASS |
|
|
Dispenser and tank monitor wiring. Phone #: ###-#### Inspection requested via web by Paul White All conduits installed by others. This permit covers wiring, sealing, and functioning pumps, tanks emergency systems. Rough in ok cover
|
ELE17-02787
| Final | 12/8/2017 | 12/11/2017 | 12/11/2017 12:54:22 PM | A | NH |
|
|
Please call Eric ###-#### for access Phone #: ###-#### Inspection requested via web by Emmet Bushman Called contact number for access and reached and voicemail for Mike not Eric. Called contractor and he was unable to reach contact. Will reschedule
|
ELE17-03548
| Final | 12/11/2017 | 12/11/2017 | 12/11/2017 10:21:38 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Kevin Perez . 210.12- AFCI protection needed for circuit extension in basement bedroom. Thru door receptacles to right. 314.20- Spark ring needed on basement column to left or box shall be flush. 422.30- A disconnecting means shall be provide for hardwired appliances. 110.15 lockout acceptable.
|
ELE17-03513
| Electrical Rough-In | 12/10/2017 | 12/11/2017 | 12/11/2017 9:30:31 AM | A | PASS |
|
|
Heated tile floor inspection in bathrooms Phone #: ###-#### Inspection requested via web by Ben Archibald Floor heat 2 bathrooms rough in ok cover
|
ELE17-04136
| Temporary Service | 12/8/2017 | 12/11/2017 | 12/11/2017 9:18:54 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn t/s u/g n ok
|
ELE17-04135
| Temporary Service | 12/8/2017 | 12/11/2017 | 12/11/2017 9:18:29 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn t/s u/g n ok
|
ELE17-04141
| Electrical Rough-In | 12/10/2017 | 12/11/2017 | 12/11/2017 8:47:12 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brad Girard Entry wall on right, down hall to left for wall near printing area. wall rough in ok cover
|
ELE17-04028
| Electrical Rough-In | 12/8/2017 | 12/11/2017 | 12/9/2017 9:51:01 AM | A | CANC |
|
|
As early as possible would be appreciated. Phone #: ###-#### >> Inspection requested via web by Matt Frey Inspection cancelled from web by: Matt Frey
|