Inspections for the day of: Monday, December 11, 2017.
Number of inspections: 26
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC17-05526 Final12/11/201712/11/201712/11/2017 4:15:06 PMPPASS
MEC17-05526 Pressure Test12/11/201712/11/201712/11/2017 4:14:31 PMPPASS
Phone #: ###-#### Inspection requested via web by Chris Field- 20lb gas pass- homeowner had CO detectors
MEC17-05383 Rough-in12/11/201712/11/201712/11/2017 3:53:29 PMPNR
Barrie Phone #: ###-####- need to add 2 exhaust fans and 1 other to permit for misc ducting- installer still completing fans
MEC17-05538 Rough-in12/11/201712/11/201712/11/2017 3:30:55 PMPCANC
Inspection requested via web by Floyd Floyd Peek - per phone call with Max to cancel inspection- will reschedule
MEC17-05538 Pressure Test12/11/201712/11/201712/11/2017 3:30:23 PMPPASS
Thank you! Inspection requested via web by Floyd Floyd Peek- 20lb gas pass- 5lb flue pass
MEC17-05186 Pressure Test12/11/201712/11/201712/11/2017 3:12:35 PMPPASS
Phone #: ###-#### Inspection requested via web by Nicholas Paige- 60lb gas pass to whole system- tagged meter- regulator needs installed in furnace room will look at on final- tube heaters ok
MEC17-05542 Final12/11/201712/11/201712/11/2017 3:07:08 PMPFAIL
Phone #: ###-#### Inspection requested via web by Paul Lawson- need drip leg on gas line between shut off valve and appliance- need to install b vent per manufactures instructions- need to brace b vent where penetrates thru roof-
MEC17-05221 Final12/11/201712/11/201712/11/2017 2:52:49 PMPPART
Phone #: ###-#### Inspection requested via web by MICHAEL BYERS- need other mech final inspections done before can close this permit out-
MEC17-05541 Final12/11/201712/11/201712/11/2017 2:28:57 PMPPASS
Phone #: ###-#### Inspection requested via web by Kristin Dolan- furnace A/C CO ok
MEC17-05541 Pressure Test12/11/201712/11/201712/11/2017 2:28:23 PMPCANC
Phone #: ###-#### Inspection requested via web by Kristin Dolan- not needed
MEC17-05314 Rough-in12/11/201712/11/201712/11/2017 1:55:28 PMPFAIL
Phone #: ###-#### Inspection requested via web by Konrad Swartz
1) b vent needs to extend 6" down below ceiling in furnace closet
2) dryer vent ducting exceeds 35'- reroute or booster fan
3)fresh air to R/A plenum un dersized per manual J
4) flex to master closet pinched at take off-
5)range hood ducting broke at 90 degree el at roof, needs to extend below ceiling and strap accordingly
6) lineset needs ran out

left correction notice front entry window
MEC17-05314 Pressure Test12/11/201712/11/201712/11/2017 1:50:09 PMPPASS
Phone #: ###-#### Inspection requested via web by Konrad Swartz- 20 lb gas pass-
MEC17-05448 Final12/5/201712/11/201712/11/2017 1:26:08 PMPPASS
PLEASE CALL INSTALLER, DWIGHT, BEFORE ARRIVAL TO ENSURE JOB IS FINISHED ###-#### Phone #: ###-#### Inspection requested via web by Rick Borg- furnace A/C CO ok
MEC17-04293 Rough-in12/11/201712/11/201712/11/2017 1:18:44 PMPPASS
CALL MANNY 20 MIN ADVANCE
WORK SHOULD BE COMPLETED BY 3 PM Phone #: ###-#### Inspection requested via web by Manuel Canto- dryer ex ok- 20lb gas pass- 5lb flue for W/H pass- 2 bath fans ok with radiant dampers in eaves- ok to cover laundry and bathroom
MEC17-05524 Final12/11/201712/11/201712/11/2017 11:46:07 AMPCANC
Ready. Please call on way. Brock ###-####. Phone #: ###-#### Inspection requested via web by Krista Boss- should have been rough in inspection- range hood needs installed and hooked up to final
MEC17-05524 Rough-in12/11/201712/11/201712/11/2017 11:45:21 AMPPASS
Ready. Please call on way. Brock ###-####. Phone #: ###-#### Inspection requested via web by Krista Boss- gas line under 10'- range hood rough in ok
MEC17-04236 Final12/11/201712/11/201712/11/2017 11:30:35 AMAPASS
MEC17-04236 Pressure Test12/11/201712/11/201712/11/2017 11:30:26 AMAPASS
5lb flue pass
MEC17-05529 Final12/8/201712/11/201712/11/2017 10:58:53 AMAPASS
Replaced old wood burning stove with new wood burning stove Phone #: ###-#### Inspection requested via web by Justin Welty- per phone call to fireplace company install of single wall pipe correct
MEC17-05475 Final12/7/201712/11/201712/11/2017 10:04:37 AMAFAIL
Inspection requested via web by Margie Rowe- need to witness flue test
MEC17-03774 Final12/8/201712/11/201712/11/2017 9:40:28 AMAPASS
PLEASE CALL OWEN WHEN 30 MINS IN ROUTE. HE WILL BE MEETING YOU THERE TO PERFORM PRESSURE TEST AND WITNESSED BY INSPECTOR. WE ARE ALSO HAVING PLUMBING FINAL INSPECTION FOR THIS AT SAME TIME BY ALL STAR PLUMBING. Phone #: ###-#### Inspection requested via web by Rick Montgomery- 5lb flue pass
MEC17-00089 Final12/8/201712/11/201712/11/2017 8:56:39 AMACANC
Phone #: ###-#### >> Inspection requested via web by Marisa Hone Inspection cancelled from web by: Marisa Hone
MEC17-04236 Final12/5/201712/11/201712/11/2017 8:53:47 AMACANC
we need to be there to perform a pressure test can you please call me and let me know when u will be there so we can meet you there. customer is elderly and AM is best. call either ###-#### or ###-#### Phone #: ###-#### Inspection requested via web by Marisa Hone- see pressure test info
MEC17-04236 Pressure Test12/5/201712/11/201712/11/2017 8:53:11 AMAFAIL
we need to be there to perform a pressure test can you please call me and let me know when u will be there so we can meet you there. customer is elderly and AM is best. call either ###-#### or ###-#### Phone #: ###-#### Inspection requested via web by Marisa Hone- not holding pressure- need to reschedule when fixed- per conversation with Jesse installer
MEC17-05319 Final12/11/201712/11/201712/11/2017 8:35:51 AMAPASS
corrections made
MEC17-03923 Final12/7/201712/11/201712/8/2017 6:41:52 AMACANC
Phone #: ###-#### >> Inspection requested via web by dannyel chaloupka Inspection cancelled from web by: dannyel chaloupka