Inspections for the day of: Thursday, December 12, 2002.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorPat Lass
TitleELE-INSPECTOR
Phone #794-9478
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE01-02245 ELE-Aging Inspection12/12/200212/12/200212/12/2002 12:00:00 AM PASS
ELE01-02387 ELE-Aging Inspection12/12/200212/12/200212/12/2002 12:00:00 AM FAIL
ELE01-02541 ELE-Aging Inspection12/12/200212/12/200212/12/2002 12:00:00 AM FAIL
ELE02-01401 Final12/11/200212/12/200212/12/2002 12:00:00 AMAPASS
CAROLYN ###-####
ELE02-02910 Final12/11/200212/12/200212/12/2002 12:00:00 AMAFAIL
Phone #: ###-#### Internet Inspection Request from: Rita DeYoung
210.8 Ground-Fault Circuit-Interrupter Protection for Personnel.
FPN:See 215.9 for ground-fault circuit-interrupter protection for personnel on feeders.
(A) Dwelling Units. All 125-volt, single-phase, 15- and 20-ampere receptacles installed in the locations specified in (1) through (8) shall have ground-fault circuit-interrupter protection for personnel.

210.70 Lighting Outlets Required.
(A) Dwelling Units. In dwelling units, lighting outlets shall be installed in accordance with 210.70(A)(1), (2), and (3).
(2) Additional Locations. Additional lighting outlets shall be installed in accordance with (a), (b), and (c).
(c) Where one or more lighting outlet(s) are installed for interior stairways, there shall be a wall switch at each floor level, and landing level that includes an entry way, to control the lighting outlet(s) where the stairway between floor levels has six risers or more.

Every thing must work for final inspection. (Whole house fan and outside fan-light)
12/12/2002 10:09:47 AM
ELE02-03842 Permanent Service12/11/200212/12/200212/12/2002 12:00:00 AMAPART
###-####
P/S U/G R Ok for power 12/11/2002 3:39:23 PM
ELE02-03844 Electrical Rough-In12/11/200212/12/200212/12/2002 12:00:00 AMPPASS
###-####- shawn
ELE02-03816 Electrical Rough-In12/12/200212/12/200212/12/2002 12:00:00 AMPPASS
Called about light at back door
ELE02-03841 Final12/12/200212/12/200212/12/2002 12:00:00 AMPPASS
###-####
ELE02-03816 Final12/12/200212/12/200212/12/2002 12:00:00 AMPNR
###-#### dawn
ELE01-04078 Electrical Rough-In12/12/200212/12/200212/12/2002 12:00:00 AMPNR
STILL WORKING ON HOUSE-RECEIVED P/C
ELE02-03092 Final12/12/200212/12/200212/12/2002 12:00:00 AMPFAIL
CALL 1/2 HR BEFORE INSP PLEASE--- GARY ###-####
3-way on fanlight not working. 12/12/2002 3:47:19 PM
ELE02-03185 Final12/12/200212/12/200212/12/2002 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 12/12/2002 at 10:30:02. Contact: ###-####.
ELE02-03846 Final12/12/200212/12/200212/12/2002 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 12/12/2002 at 11:03:37. Contact: ###-####.