ELE04-03894
| Final | 12/10/2004 | 12/13/2004 | 12/13/2004 12:00:00 AM | A | FAIL |
|
|
Not home until 8:20 A.M.; Phone #: ###-#### Internet Inspection Request from: Dana Moyer called need to meet contractor 12/13/2004 9:58:43 AM
|
ELE04-03897
| Final | 12/10/2004 | 12/13/2004 | 12/13/2004 12:00:00 AM | A | PASS |
|
|
Request final inspection Thank you.; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH ok 12/13/2004 10:27:49 AM
|
ELE04-02558
| Final | 12/12/2004 | 12/13/2004 | 12/13/2004 12:00:00 AM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 12/12/2004 at 6:13:10 PM. Contact: ###-####. cor. posted met contractor, 210.11(C)(3) remove outside gfci from bathroom circuit, 110.12(A) seal breaker KO 12/13/2004 9:00:55 AM
|
ELE04-03815
| Rough-In Permanent Service | 12/13/2004 | 12/13/2004 | 12/13/2004 12:00:00 AM | A | PASS |
|
|
Internet Inspection Request from: Bob Glenn r/i ok p/s u/g new ok 12/13/2004 10:38:28 AM
|
ELE04-03213
| Electrical Rough-In | 12/13/2004 | 12/13/2004 | 12/13/2004 12:00:00 AM | P | PART |
|
|
Clyde; Phone #: ###-#### Internet Inspection Request from: Jan Rice walls and ceiling ok , needs GEC from p/s to electrode at garage and main breaker cor. posted called 12/13/2004 1:21:49 PM
|
ELE04-03903
| Final | 12/13/2004 | 12/13/2004 | 12/13/2004 12:00:00 AM | P | CANC |
|
|
dAVE-LATE AFTERNOON; Phone #: ###-#### Internet Inspection Request from: Jan Rice Cancel Dave 12/13/2004
|
ELE04-03577
| Temporary Service | 12/13/2004 | 12/13/2004 | 12/13/2004 12:00:00 AM | P | PASS |
|
|
Justin; Phone #: ###-#### Internet Inspection Request from: Jan Rice ok t/s o/h new ok 12/13/2004 12:39:12 PM
|
ELE04-03575
| Temporary Service | 12/13/2004 | 12/13/2004 | 12/13/2004 12:00:00 AM | P | PASS |
|
|
Justin; Phone #: ###-#### Internet Inspection Request from: Jan Rice ok t/s o/h new ok 12/13/2004 12:39:27 PM
|
ELE04-03908
| Electrical Rough-In | 12/13/2004 | 12/13/2004 | 12/13/2004 12:00:00 AM | P | PASS |
|
|
lars; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles walls and ceiling ok 12/13/2004 2:48:08 PM
|
ELE04-03894
| Electrical Rough-In | 12/13/2004 | 12/13/2004 | 12/13/2004 12:00:00 AM | P | PART |
|
|
cor. posted 300.10&12 electrical and mechanical continuity between p/s and sub panel 250.24(A) terminate GEC to neutral bus not lug on p/s enclosure, 408.21 shall not double up neutrals
|
ELE04-03894
| Permanent Service | 12/13/2004 | 12/13/2004 | 12/13/2004 12:00:00 AM | P | PASS |
|
|
p/s o/h rec. ok
|
ELE04-03796
| Electrical Rough-In | 12/10/2004 | 12/13/2004 | 12/13/2004 12:00:00 AM | P | PASS |
|
|
Vivian; Phone #: ###-#### Internet Inspection Request from: Jan Rice r/i ok all units
p/s u/g new ok 12/13/2004 4:31:51 PM
|