ELE06-04447
| Electrical Rough-In | 12/13/2006 | 12/13/2006 | 12/13/2006 4:16:16 PM | P | PASS |
|
|
Work performed by Steve Johnson.; Phone #: ###-#### Internet Inspection Request from: Matt Santacruz ri ok , see final
|
ELE06-04447
| Final | 12/13/2006 | 12/13/2006 | 12/13/2006 4:15:42 PM | P | PASS |
|
|
Work performed by Steve Johnson.; Phone #: ###-#### Internet Inspection Request from: Matt Santacruz ok to final
|
ELE06-04189
| Final | 12/13/2006 | 12/13/2006 | 12/13/2006 3:06:29 PM | P | PASS |
|
|
Daryl; Phone #: ###-#### Internet Inspection Request from: Sherri Bennett ok to final
|
ELE06-04542
| Final | 12/13/2006 | 12/13/2006 | 12/13/2006 2:23:52 PM | P | FAIL |
|
|
CONTACT: CHRIS CARMINE; Phone #: ###-#### Internet Inspection Request from: Deb McCoy met contr, called 324, left corr notice, BCC 4-05-33(A)(B) all equipment shall be listed by a nationally recognized testing laboratory, NEC 110.3(A) equipment shall be suitable for installation, NOTE: 1. All wiring shall be done by a licensed electrical contractor, 2. all wiring methods shall be per NEC, 3, Do not energize. Unit pre-built, can't see wiring except in closet. Told elect all circuits would have to be gfci if ok to energize.
|
ELE06-04399
| Electrical Rough-In | 12/13/2006 | 12/13/2006 | 12/13/2006 1:14:02 PM | P | CANC |
|
|
Mark; Phone #: ###-#### Internet Inspection Request from: Sherri Bennett wrong type request, see p/s
|
ELE06-04399
| Permanent Service | 12/13/2006 | 12/13/2006 | 12/13/2006 1:13:26 PM | P | PASS |
|
|
Mark; Phone #: ###-#### Internet Inspection Request from: Sherri Bennett p/s exst meter pak n ok
|
ELE06-04569
| Electrical Rough-In | 12/13/2006 | 12/13/2006 | 12/13/2006 12:51:56 PM | P | PASS |
|
|
Extended an existing garage ckt. to a mew receptacle for a grg. door opener. Also extended an existing switch leg to the living room for the paddle fan / light combo, and used a fansafe box. Tech/Dan/###-#### (6121199ci) Thanks !!!; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell ri ok, see final
|
ELE06-04569
| Final | 12/13/2006 | 12/13/2006 | 12/13/2006 12:50:59 PM | P | PASS |
|
|
Extended an existing garage ckt. to a mew receptacle for a grg. door opener. Also extended an existing switch leg to the living room for the paddle fan / light combo, and used a fansafe box. Tech/Dan/###-#### (6121199ci) Thanks !!!; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell ri ok, ok to final
|
ELE06-04476
| Conference | 12/12/2006 | 12/13/2006 | 12/13/2006 10:56:15 AM | A | DONE |
|
|
Requesting conference for service change on existing residence. Will be at job by 8:30 wednesday!; Phone #: ###-#### Internet Inspection Request from: Lynn Solmon reviewed service size, gndg, possible feeder for shop, mounting height, new meter base for height for panel
|
ELE06-04508
| Electrical Rough-In | 12/8/2006 | 12/13/2006 | 12/13/2006 10:24:13 AM | A | FAIL |
|
|
Work performed by Ron Chaney.; Phone #: ###-#### Internet Inspection Request from: Matt Santacruz called contr, nec 680.22(A)(3) recpt shall be minimum 10' from inside wall of tub, blank off recpt and relocate new one since exst trips kitchen gfci
|
ELE06-04257
| Permanent Service | 12/12/2006 | 12/13/2006 | 12/13/2006 9:31:09 AM | A | PASS |
|
|
please ontact Shane, thank you; Phone #: ###-#### Internet Inspection Request from: Wendy Waters p/s exst meter pak n ok
|
ELE06-04056
| Final | 12/12/2006 | 12/13/2006 | 12/13/2006 9:05:35 AM | A | PASS |
|
|
Spencer; Phone #: ###-#### Internet Inspection Request from: Sherri Bennett talked to contr to add recpt at end of peninsula, ok to final
|
ELE06-03809
| Final | 12/12/2006 | 12/13/2006 | 12/13/2006 8:43:55 AM | A | FAIL |
|
|
Roof access is in mechanical room. Any questions, call Derrick at ###-####; Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot called , told derrick gfci not working, 1 unit not hooked up, breaker trips, also told to get permanent labels on disconnects
|
ELE06-00113
| Electrical Rough-In | 12/12/2006 | 12/13/2006 | 12/13/2006 8:42:11 AM | A | PASS |
|
|
Greg, ###-#### work located in the new mechanical area ric walls only anop ok, new mech room
|