Inspections for the day of: Wednesday, December 13, 2017.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-03473 Electrical Rough-In12/13/201712/13/201712/13/2017 2:32:34 PMPPASS
Underground Inspection for service Phone #: ###-#### Inspection requested via web by Kevin Perez
110.3- Expansion joints shall be installed as per manufacturers instructions. Installed upside down. Bell end shall be positioned as to not collect moisture or dirt.
225.32- A disconnecting means shall be provided on house at a readily accessible location either outside on inside at nearest point of entrance of conductors.
expansion joists located above grade. Verbal with Tom on corrections for final.
Underground rough in ok cover
ELE17-04187 Final12/13/201712/13/201712/13/2017 1:27:52 PMPNR
George Morris is contact on site, ###-#### Phone #: ###-#### Inspection requested via web by Debby Pierce
Branch circuit terminations not complete. Will call when complete.
ELE17-04186 Final12/13/201712/13/201712/13/2017 1:27:10 PMPNR
George Morris is contact on site, ###-####. Phone #: ###-#### Inspection requested via web by Debby Pierce
Branch circuit terminations not complete. Will call when ready.
ELE17-04187 Permanent Service12/13/201712/13/201712/13/2017 12:28:22 PMPPASS
George Morris is contact on site, ###-#### Phone #: ###-#### Inspection requested via web by Debby Pierce
Available fault current for S-2 east side.
8650 p/s u/g n ok
ELE17-04186 Permanent Service12/13/201712/13/201712/13/2017 12:27:02 PMPPASS
George Morris is contact on site, ###-####. Phone #: ###-#### Inspection requested via web by Debby Pierce
Available fault current for S-1 west side. 3675 p/s u/g n ok
ELE17-03784 Electrical Rough-In12/13/201712/13/201712/13/2017 12:24:31 PMAPASS
Bathroom ceiling inspection Phone #: ###-#### Inspection requested via web by Debby Pierce
Bathroom drop ceilings rough in ok cover
ELE17-04177 Temporary Service12/12/201712/13/201712/13/2017 10:42:39 AMAPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk
t/s u/g n ok
ELE17-04155 Rough-In Permanent Service12/12/201712/13/201712/13/2017 10:42:13 AMAPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk
Rough in ok cover p/s u/g n ok
ELE17-04027 Conference12/12/201712/13/201712/13/2017 10:02:56 AMADONE
Consultation request Phone #: ###-#### Inspection requested via web by Steve Craig
Discussed the required spacing for showroom window receptacles. Asked if maximum space for required receptacles could be increased to mount on columns. 210.62 states max spacing shall not exceed 12'. Shall not exceed 12' spacing between receptacles.
ELE17-03348 Final12/12/201712/13/201712/13/2017 9:07:05 AMAPASS
Cell Tower final inspection.
Contact Matt Hannum.
Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek Final ok
ELE17-03348 Electrical Rough-In12/13/201712/13/201712/13/2017 9:06:46 AMPPASS
Cell Tower final inspection.
Contact Matt Hannum.
Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek
Surface roof conduit and circuit to attenna rough in ok