MEC12-01393
| Mec-Aging Inspection | 12/14/2012 | 12/14/2012 | 12/18/2012 9:14:10 AM | | PEND |
|
|
harold is just starting the job
|
GCM12-00246
| GCM-Final | 12/12/2012 | 12/14/2012 | 12/18/2012 9:03:57 AM | A | NR |
|
|
John Burks @ ###-####...john will reschedule
|
MEC12-04215
| Final | 12/13/2012 | 12/14/2012 | 12/14/2012 4:24:14 PM | P | FAIL |
|
|
1:30 meet ronnie...the comb air needs to be 8" and be in the upper 12" of the enclosure
|
GCM12-00197
| GCM-Final | 12/14/2012 | 12/14/2012 | 12/14/2012 4:11:00 PM | P | FAIL |
|
|
###-####...need to strap w/h flue for support
|
MEC12-04411
| Final | 12/12/2012 | 12/14/2012 | 12/14/2012 3:34:27 PM | A | PASS |
|
|
final inspection scheduled 12/14/12am. Phone #: ###-#### >> Inspection requested via web by Echo Jackson
|
MEC12-04420
| Final | 12/14/2012 | 12/14/2012 | 12/14/2012 2:13:08 PM | P | PASS |
|
|
call john with questions Phone #: ###-#### >> Inspection requested via web by Nicholas Paige
|
MEC12-00047
| Final | 12/11/2012 | 12/14/2012 | 12/14/2012 1:40:05 PM | P | PASS |
|
|
1:30 meet susan...checked venting on existing w/h
|
MEC12-04400
| Final | 12/13/2012 | 12/14/2012 | 12/14/2012 12:01:31 PM | A | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by Joe Bertwell...f/p covered up
|
MEC12-04509
| Final | 12/13/2012 | 12/14/2012 | 12/14/2012 11:23:04 AM | A | PASS |
|
|
Please call Russ for access: ###-#### Phone #: ###-#### >> Inspection requested via web by Frank Marturello
|
MEC12-04520
| Rough-in | 12/13/2012 | 12/14/2012 | 12/14/2012 10:17:01 AM | A | PART |
|
|
ready Phone #: ###-#### >> Inspection requested via web by Russ Curtis...20lb gas and f/p ok....the dryer vent came apart and is hanging in the attic...need to re-tape and strap it for support....CHECK DUCT BLASTER AT FINAL
|
MEC12-04531
| Final | 12/13/2012 | 12/14/2012 | 12/14/2012 9:53:30 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Lori Michel....20lb gas to future bbq and gas log ok
|
GCM12-00238
| GCM-Rough In & Pressure Test | 12/13/2012 | 12/14/2012 | 12/14/2012 9:25:39 AM | A | PASS |
|
|
April @ ###-####....r/i and 20lb gas ok....venting on tankless w/h ok....CHECK DUCT BLASTER AT FINAL
|