Inspections for the day of: Monday, December 14, 2015.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Story
TitleELE-INSPECTOR
Phone #985-3493
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-02529 ELE-Aging Inspection12/14/201512/14/201512/17/2015 10:44:21 AM CANC
too busy
ELE12-00194 ELE-Aging Inspection12/14/201512/14/201512/17/2015 10:44:02 AM CANC
too busy
ELE12-00212 ELE-Aging Inspection12/14/201512/14/201512/17/2015 10:43:44 AM CANC
too busy
ELE12-02415 ELE-Aging Inspection12/14/201512/14/201512/17/2015 10:43:26 AM CANC
too busy
ELE15-04000 Electrical Rough-In12/14/201512/14/201512/14/2015 2:02:40 PMPPASS
Inspection requested via web by Gene Wright underground for well ok cover
ELE15-03603 Final12/14/201512/14/201512/14/2015 1:51:24 PMPPASS
Ready for final Phone #: ###-#### Inspection requested via web by Kevin Oderkirk kitchen final ok
ELE15-01742 Final12/14/201512/14/201512/14/2015 1:12:43 PMPPASS
Phone #: ###-#### Inspection requested via web by Mike Cole final ok
ELE15-03741 Final12/13/201512/14/201512/14/2015 10:21:20 AMAFAIL
This is for a final. Phone #: ###-#### Inspection requested via web by Brian Hughes 230.24 overhead service conductors shall maintain 36" from windows
ELE15-01056 Final12/13/201512/14/201512/14/2015 9:40:58 AMAFAIL
Garage code is 1201. James will be available by phone. Tim will also be in and out of the residence all day long. His number is ###-####.

Phone #: ###-#### Inspection requested via web by John Harvey 210.8 (3) all outdoor receptacles shall have GFCI protrection-210.8 (7) all receptacles located wihin 6' of a sink shall have GFCI protection-210.8 (5) all 120v receptacles in a unfinished basement shall have GFCI protection-422.31 all permanently installed appliances shall have a means of lockout(dishwasher and hood) 406.12 all receptacles shall be tamper resistant(a few down stairs)-314.20 recessed boxes in tile shall have a listed extender-250.94 intersystem bond required-680.22 no receptacles shall be located within 6' of a hot tub
ELE15-02905 Final12/12/201512/14/201512/14/2015 8:56:51 AMAPASS
home owner will be home Phone #: ###-#### Inspection requested via web by Jesse Fuentes final ok