Inspections for the day of: Wednesday, December 14, 2016.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC16-05257 Final12/7/201612/14/201612/14/2016 4:28:36 PMPPASS
Please call Jessie at ###-#### before arriving, thank you. Phone #: ###-#### Inspection requested via web by TERESA HUTTO
MEC16-05589 Final12/14/201612/14/201612/14/2016 4:01:03 PMPNR
This is for late pm please Phone #: ###-#### Inspection requested via web by Dustin Rich- still installing
MEC16-05583 Final12/13/201612/14/201612/14/2016 3:39:28 PMPPASS
Please call Scott B4 arrival to arrange time and access Phone #: ###-#### Inspection requested via web by Dustin Rich
MEC16-05594 Final12/14/201612/14/201612/14/2016 2:51:53 PMPPASS
Would like call when on way Thank you! Phone #: ###-#### Inspection requested via web by Xanti Berria
MEC16-02174 Final12/13/201612/14/201612/14/2016 2:12:59 PMPFAIL
Phone #: ###-#### Inspection requested via web by Amanda Farnsworth- for temp occupancy need all life safety issuses taken care of- equipment needs to be running operation
MEC16-05567 Final12/13/201612/14/201612/14/2016 1:37:35 PMPPASS
This is for late pm, please call David ###-#### B4 arrival to arrange time and access Phone #: ###-#### Inspection requested via web by Dustin Rich
MEC16-05296 Rough-in12/13/201612/14/201612/14/2016 11:15:58 AMAPASS
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN- equipment not set
MEC16-05296 Pressure Test12/14/201612/14/201612/14/2016 11:15:14 AMAPASS
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN- 20lb gas pass- 5lb flue pass
MEC16-05545 Final12/13/201612/14/201612/14/2016 11:00:55 AMAPASS
Please call Don at ###-#### or ###-#### before arriving, thank you. Phone #: ###-#### Inspection requested via web by TERESA HUTTO
MEC16-04277 Conference12/13/201612/14/201612/14/2016 10:34:00 AMAPASS
10 am about make up air for range hood kitchen fan
MEC16-05194 Final12/13/201612/14/201612/14/2016 10:03:24 AMAPASS
Chris Phone #: ###-####
MEC16-05581 Rough-in12/13/201612/14/201612/14/2016 9:14:41 AMAFAIL
Call Eric with any issues @ 412.6613 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek- csst gas pipe can not be secured in stud bays- need csst approved nail plates- exhaust fans need to be installed and hooked up- need approved manual J onsite and submitted for approval- need combustion air in furnace room- need isulation shiel on b vent in attic with 1" clearance- need 1" clearance to combustibles at roof penetration- registers in floor need mastic- flex duct in crawl needs supported better and off ground- left correction notice on front window
MEC16-05581 Pressure Test12/13/201612/14/201612/14/2016 9:10:55 AMAPASS
Call Eric with any issues @ 412.6613 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek- 20lb gas pass
MEC16-05487 Final12/13/201612/14/201612/14/2016 8:33:01 AMAPASS
Phone #: ###-#### Inspection requested via web by Devony Bullard