ELE17-01337
| Electrical Rough-In | 12/13/2017 | 12/14/2017 | 12/14/2017 1:40:21 PM | P | PASS |
|
|
We are requesting a rough-in inspection for 2nd floor walls and ceilings and 1st floor complete ceiling for tomorrow afternoon. Our contact is Rick @ ###-####. Thank you, Phone #: ###-#### Inspection requested via web by Clint Tate 219 thru 234 and 238, level 1 firelids except west meeting room rough in ok cover
|
ELE17-04204
| Electrical Rough-In | 12/14/2017 | 12/14/2017 | 12/14/2017 12:47:50 PM | P | PASS |
|
|
Ben Phone #: ###-#### Small wall to west of elevators rough in ok cover
|
ELE17-03734
| Electrical Rough-In | 12/13/2017 | 12/14/2017 | 12/14/2017 11:39:56 AM | A | PART |
|
|
This inspection is for temporary occupancy of the partial prep room which failed the last inspection due to the BLD permit still under review. Our understanding is this would be resolved between the Architect and City today. Site Contact: Luke Hardy, ###-####. Phone #: ###-#### Inspection requested via web by Larry Looney No rough in needed. Created to note for ok occupy prep room A.
|
ELE17-04192
| Electrical Rough-In | 12/13/2017 | 12/14/2017 | 12/14/2017 10:41:07 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ryan Wilson Under ground not in at time of inspection, Will create P/S, contractor to provide minimum clearance above garage roof as per 230.24. Swing may cross over peak of roof, may be issue. House and garage rough in ok cover
|
ELE17-04192
| Permanent Service | 12/14/2017 | 12/14/2017 | 12/14/2017 10:40:48 AM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ryan Wilson Shall provide clearance for overhead service entrance conductors as per 230.24. May cross garage roof peak may be issue called contractor to inform. p/s o/h n ok
|
ELE17-04203
| Electrical Rough-In | 12/13/2017 | 12/14/2017 | 12/14/2017 10:12:45 AM | A | FAIL |
|
|
Call Chase if needed - ###-####. Basement rough-in only Phone #: ###-#### Inspection requested via web by Cyndi Dale 300.15- All wiring shall terminate in a box. Open wiring out of flex, MC in soffit area. All covers shall be accessible after installation. 314.25- All boxes shall have covers installed. Several boxes with wiring hanging out in soffit area. 330.12- MC shall not be installed where subject to damage. MC hanging below soffit and below soffit framing member.
|
ELE17-03103
| Final | 12/14/2017 | 12/14/2017 | 12/14/2017 8:33:18 AM | A | PASS |
|
|
Garage code is 9045 Phone #: ###-#### Inspection requested via web by Kevin Heideman Final ok
|