Inspections for the day of: Thursday, December 15, 2011.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-02657 Electrical Rough-In12/15/201112/15/201112/15/2011 3:35:38 PMPPASS
ufer ground Phone #: ###-#### >> Inspection requested via web by Celinda Winters rough-in ok cover concrete encased electrode
ELE11-02824 Electrical Rough-In12/15/201112/15/201112/15/2011 3:25:29 PMPPASS
Exterior only Phone #: ###-#### >> Inspection requested via web by Therrin Robertson rough-in ok cover exterior soffets
ELE11-02823 Electrical Rough-In12/15/201112/15/201112/15/2011 3:24:12 PMPPASS
Exterior only Phone #: ###-#### >> Inspection requested via web by Therrin Robertson rough-in ok cover exterior soffets
ELE11-02816 Final12/15/201112/15/201112/15/2011 2:56:04 PMPFAIL
Contact if Bob Callahan. Please call before arrival. Thank you and have a super day! Phone #: ###-#### >> Inspection requested via web by Laura Longshaw Receptacles shall be UL listed weather resistance type with inuse cover or remove devices, Permanent service requires two ground rods,six feet apart. ok cover trench
ELE11-02804 Electrical Rough-In12/14/201112/15/201112/15/2011 2:19:22 PMPNR
Call Jeff 30 minutes before ###-#### Phone #: ###-#### >> Inspection requested via web by Don Conley
ELE11-02796 Electrical Rough-In12/14/201112/15/201112/15/2011 1:07:10 PMPNH
Please contact Michael Howard to meet you. Electrician is Dwayne ###-####. Ready to final. Phone #: ###-#### >> Inspection requested via web by joel smith
ELE11-02450 Final12/14/201112/15/201112/15/2011 9:36:36 AMAPASS
Phone #: ###-#### >> Inspection requested via web by TOM BICANDI final ok
ELE11-02815 Conference12/14/201112/15/201112/15/2011 9:18:53 AMADONE
pamela please call before going out Phone #: ###-#### Discussed with home owner service requirements for unattached building/grounding
ELE11-02557 Final12/14/201112/15/201112/15/2011 8:36:59 AMAPASS
Any questions, please call Clay. Thank You. Phone #: ###-#### >> Inspection requested via web by Clay Morgan final ok
ELE11-02812 Electrical Rough-In12/14/201112/15/201112/14/2011 5:02:53 PMAPASS
Mike Phone #: ###-#### rough-in ok UL listed lighting kits
ELE11-02814 Electrical Rough-In12/14/201112/15/201112/14/2011 4:56:56 PMAPASS
Mike Phone #: ###-#### rough-in ok UL listed lighting kits
ELE11-02813 Electrical Rough-In12/14/201112/15/201112/14/2011 4:54:29 PMAPASS
Mike Phone #: ###-#### rough-in ok UL listed lighting kits