ELE17-04220
| Final | 12/15/2017 | 12/15/2017 | 12/15/2017 2:53:16 PM | P | CANC |
|
|
Inspection for power to be restored. Please call Alloway office at ###-#### for access Phone #: ###-#### Inspection requested via web by steve ragan Needed p/s
|
ELE17-04220
| Permanent Service | 12/15/2017 | 12/15/2017 | 12/15/2017 2:53:09 PM | P | PASS |
|
|
Inspection for power to be restored. Please call Alloway office at ###-#### for access Phone #: ###-#### Inspection requested via web by steve ragan p/s u/g rec ok, no meter needed just turn main on
|
ELE17-04039
| Permanent Service | 12/15/2017 | 12/15/2017 | 12/15/2017 2:52:13 PM | P | PASS |
|
|
Installed 2 eight foot grounding rods. Morning or afternoon is fine. I''m five minutes away Phone #: ###-#### Inspection requested via web by Gail Hofert p/s o/h rec ok
|
ELE17-03442
| Electrical Rough-In | 12/14/2017 | 12/15/2017 | 12/15/2017 2:51:46 PM | P | PASS |
|
|
UG // Jake Phone #: ###-#### Phase 1 underground ok to cover
|
ELE17-04022
| Rough-In Permanent Service | 12/14/2017 | 12/15/2017 | 12/15/2017 11:10:40 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mike Okamura Underground to garage ok to cover p/s u/g n ok
|
ELE17-04023
| Rough-In Permanent Service | 12/14/2017 | 12/15/2017 | 12/15/2017 11:10:10 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mike Okamura Underground ok to cover to detached garage p/s u/g n ok
|
ELE17-04024
| Rough-In Permanent Service | 12/14/2017 | 12/15/2017 | 12/15/2017 11:09:33 AM | A | PASS |
|
|
Inspection requested via web by Mike Okamura Underground to garage ok to cover p/s u/g n ok
|
ELE17-04021
| Rough-In Permanent Service | 12/14/2017 | 12/15/2017 | 12/15/2017 11:09:01 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mike Okamura Underground to garage ok to cover p/s u/g n ok
|
ELE17-03663
| Final | 12/12/2017 | 12/15/2017 | 12/15/2017 9:52:04 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mike Okamura Corrections fixed final ok
|
ELE17-04178
| Final | 12/12/2017 | 12/15/2017 | 12/15/2017 9:51:36 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mike Okamura Attached garage final ok
|
ELE17-04191
| Permanent Service | 12/14/2017 | 12/15/2017 | 12/15/2017 9:23:26 AM | A | FAIL |
|
|
Service inspection so service can be re-energized. Unit should be open by 9:00 by general contractor. Phone #: ###-#### Inspection requested via web by David Nelson 110.24 AFC calculation required proir to service being energized. Need to verify main bonding jumper in main service gear no access inside to see it
|
ELE17-04214
| Electrical Rough-In | 12/14/2017 | 12/15/2017 | 12/15/2017 9:00:16 AM | A | PASS |
|
|
Luke-partial on the walls only Phone #: ###-#### Remaining walls not framed will be called inn on another date... Walls and soffits@floor boxes ok to cover, Electricain will remove existing buried receptacles in walls and cut wires of to insure they are dead and not in use....
|
ELE17-03762
| Final | 12/14/2017 | 12/15/2017 | 12/15/2017 8:45:08 AM | A | PASS |
|
|
All items done, Final ok
|