ELE13-03462
| Rough-In Permanent Service | 12/17/2013 | 12/17/2013 | 12/17/2013 3:01:33 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Darryn Coburn corrections made. ri ok, p/s u/g n ok
|
ELE13-03498
| Permanent Service | 12/17/2013 | 12/17/2013 | 12/17/2013 2:33:22 PM | P | FAIL |
|
|
Lock box 3811, Please leave detailed red tag for insurance company, let me know if you have any questions. Thanks Clay ###-#### Phone #: ###-#### >> Inspection requested via web by Clay Morgan left correction notice, BCC no violations shall be retained, NEC 240.24(D) panel shall not be in closet, 250 shall bring grounding up to code, 210 shall provide current outlet spacing and gfci protection, 358 shall strap EMT per code
|
ELE13-03268
| Final | 12/16/2013 | 12/17/2013 | 12/17/2013 1:20:22 PM | P | PASS |
|
|
will be open Phone #: ###-#### >> Inspection requested via web by mike brown called, ok final
|
ELE13-03389
| Final | 12/16/2013 | 12/17/2013 | 12/17/2013 12:34:43 PM | P | PART |
|
|
AREA BEHIND BREAK ROOM TURNED INTO OPEN WORK AREA Phone #: ###-#### >> Inspection requested via web by MARK PINNEY checked ceiling, shall recall when furniture being installed to check listing
|
ELE13-02898
| Final | 12/16/2013 | 12/17/2013 | 12/17/2013 9:56:56 AM | A | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by Therrin Robertson called, left correction notice, NEC 410.16(C((2) shall provide minimum 6" clearance from fixture to edge of storage in mbr closet, 110.26 shall provide clearance in front of service equipment
|
ELE13-03477
| Electrical Rough-In | 12/16/2013 | 12/17/2013 | 12/17/2013 8:49:30 AM | A | PASS |
|
|
Ufer inspection/pouring 10 - Bill Phone #: ###-#### rebar to turn up
|
ELE13-03488
| Temporary Service | 12/16/2013 | 12/17/2013 | 12/17/2013 8:26:21 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Rhonda Zamagni t/s u/g n ok
|