Inspections for the day of: Tuesday, December 17, 2013.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTroy James
TitleMEC-COM/RES INSPECTOR
Phone #794-9461
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC13-05339 Final12/17/201312/17/201312/17/2013 3:21:59 PMPPASS
Need a pressure test and final please. Aleks ###-####
Thanks Phone #: ###-#### >> Inspection requested via web by Allie Courter
MEC13-05289 Rough-in12/17/201312/17/201312/17/2013 2:54:52 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Brad Allison
20# gas test and flue test ok
MEC13-05341 Rough-in12/17/201312/17/201312/17/2013 2:53:41 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Dan Otero
MEC13-05083 Rough-in12/16/201312/17/201312/17/2013 2:22:24 PMPFAIL
Please contact owner for access ###-#### or ###-####.
Contact Ryan with questions ###-####. Phone #: ###-#### >> Inspection requested via web by Lea Briggs
Need a revised manual j.
MEC13-05152 Rough-in12/17/201312/17/201312/17/2013 1:20:04 PMPFAIL
>> Inspection requested via web by Dan Otero
C/N posted in firebox. Unable to verify combustion air duct is UL 181 class 0 or 1 fire rating. Duct not labeled. Metal fire strips not isntalled per manufacturer requirements.
MEC13-04428 Final12/17/201312/17/201312/17/2013 12:48:57 PMPPASS
CONTACT IS RILEY ###-#### Phone #: ###-#### >> Inspection requested via web by LENNIE BUSS
MEC13-04905 Final12/17/201312/17/201312/17/2013 12:48:38 PMPPASS
MEC13-05260 Final12/17/201312/17/201312/17/2013 12:31:35 PMPPASS
Call John ###-#### for access >> Inspection requested via web by John Bertram
MEC13-04631 Rough-in12/16/201312/17/201312/17/2013 11:32:12 AMPPART
Rough in please call Matt Hines with any questions ###-#### Phone #: ###-#### >> Inspection requested via web by Sarah Rhodes..OK TO COVER CEILINGS EXCEPT AT HOODS
MEC13-04798 Final12/16/201312/17/201312/17/2013 11:13:25 AMACANC
Please call Gary with any questions. Phone #: ###-#### >> Inspection requested via web by Rhonda Marcum
have not completed clearance reduction at ceiling above hood
MEC13-04778 Final12/16/201312/17/201312/17/2013 11:12:36 AMACANC
Please call Gary with any questions. Phone #: ###-#### >> Inspection requested via web by Rhonda Marcum
have not completed clearance reduction to ceiling above hood
MEC13-05001 Final12/16/201312/17/201312/17/2013 11:09:39 AMAPASS
Please call Gary with any questions. Phone #: ###-#### >> Inspection requested via web by Rhonda Marcum
MEC13-03688 Rough-in12/16/201312/17/201312/17/2013 10:19:30 AMAPASS
JOB CONTACT - JOSH ###-#### Phone #: ###-#### >> Inspection requested via web by BECCA DUMMER
complete rough inspection to hydronic connection to air handlers