Inspections for the day of: Tuesday, December 17, 2013.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE00-03086 Final12/16/201312/17/201312/17/2013 2:32:20 PMPFAIL
John Phone #: ###-#### NEC 406.11 All 15 and 20 ampere 120 volt receptacles shall be listed tamper-resistant . Clothes closets NEC 410.16(A)(1) recessed luminaire shall have completely enclosed lamp. Correct reverse polarity in receptacles
ELE13-03476 Rough-In Permanent Service12/16/201312/17/201312/17/2013 2:01:05 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Zane Robertson rough-in p/s u/g n ok
ELE13-02453 Final12/16/201312/17/201312/17/2013 1:35:27 PMPFAIL
John Phone #: ###-#### NEC 210.8 (2) All kitchen 15 and 20 ampere receptacles shall have GFCI protection NEC 210.52(B)(3) Kitchen countertop shall be supplied by no fewer than two small appliance branch circuits. NEC 406.11 All 15 and 20 ampere 120 volt receptacle in dwelling units shall be listed tamper resistant receptacles
ELE13-03487 Rough-In Permanent Service12/17/201312/17/201312/17/2013 1:20:59 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman rough-in p/s u/g n ok
ELE13-03473 Electrical Rough-In12/16/201312/17/201312/17/2013 12:55:30 PMAPASS
Phone #: ###-#### >> Inspection requested via web by Chris Berthelot rough-in ok cover
ELE13-03125 Electrical Rough-In12/17/201312/17/201312/17/2013 12:01:01 PMPPASS
Contact: Tom Hartung - scan room wall inspection please Phone #: ###-#### >> Inspection requested via web by Deb Gooden rough-in ok cover
ELE12-00802 ELE-Aging Inspection12/17/201312/17/201312/17/2013 10:06:05 AM DONE
still under construction
ELE12-01363 ELE-Aging Inspection12/17/201312/17/201312/17/2013 10:04:19 AM DONE
see final
ELE12-01363 Final12/17/201312/17/201312/17/2013 10:02:43 AMAPASS
UL listed sign final ok
ELE12-00316 ELE-Aging Inspection12/17/201312/17/201312/17/2013 9:57:56 AM DONE
see final
ELE12-00316 Final12/17/201312/17/201312/17/2013 9:56:56 AMAPASS
job complete, final ok
ELE13-01953 Final12/16/201312/17/201312/17/2013 9:36:29 AMAPASS
corrections made ready for final Phone #: ###-#### >> Inspection requested via web by Don Lustig job complete, final ok
ELE13-03493 Conference12/16/201312/17/201312/17/2013 9:23:43 AMADONE
Call troy Phone #: ###-#### >> Inspection requested via web by Don Conley Discussed electrical requirements for code violation area, family room,bathroom conversion
ELE13-03464 Rough-In Permanent Service12/17/201312/17/201312/17/2013 8:50:01 AMAPASS
Phone #: ###-#### >> Inspection requested via web by daniel bibikov rough-in p/s u/g n ok
ELE12-01913 Final12/10/201312/17/201312/17/2013 8:17:39 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Louis Keller job complete, final ok
ELE11-02728 ELE-Aging Inspection12/17/201312/17/201312/17/2013 7:03:39 AM DONE
still under review