BLD15-04194
| FIRE-Final Inspection | 12/17/2015 | 12/17/2015 | 12/17/2015 2:59:36 PM | P | PASS |
|
|
Life safety passed
|
FIR15-00760
| INSP-Final Inspection | 12/17/2015 | 12/17/2015 | 12/17/2015 2:27:15 PM | P | PASS |
|
|
Permit finaled
|
FIR14-00719
| INSP-Final Inspection | 12/16/2015 | 12/17/2015 | 12/17/2015 2:12:21 PM | P | FAIL |
|
|
No city approved plans or notes were on site. I walked all of the floors and verified that the notification was working. I noted that on the second floor an intermittent sound (tech Brian Anderson knows the fix). I also noted an overspaced strobe in a corridor, strobes in restrooms with tub/showers without weather proof back boxes, and strobe in Room 124 was not functioning at all. There is a wall mount horn/strobe on the first floor that is mounted at 10' or 12" feet above finish floor. I did not test any initiating devices due to no approved plans.
|
BLD15-04218
| FIRE-Final Inspection | 12/16/2015 | 12/17/2015 | 12/17/2015 11:53:11 AM | A | PASS |
|
|
Life safety passed. This space is not in a "finished" state. No sprinklers, no alarms and no occupants.
|
BLD15-00248
| FIRE-Final Inspection | 12/16/2015 | 12/17/2015 | 12/17/2015 11:15:23 AM | A | PASS |
|
|
Life safety passed
|
FIR15-00657
| INSP-Final Inspection | 12/15/2015 | 12/17/2015 | 12/17/2015 11:07:26 AM | A | PASS |
|
|
Permit finaled
|
FIR15-00802
| INSP-Final Inspection | 12/15/2015 | 12/17/2015 | 12/17/2015 11:06:53 AM | A | PASS |
|
|
Permit finaled
|
BLD15-02844
| FIRE-Final Inspection | 12/16/2015 | 12/17/2015 | 12/17/2015 9:38:40 AM | A | FAIL |
|
|
As per the review comments a fire alarm permit is required for the work to be performed on the engineered drawings. Part of the work appears to have already been done. Life safety will be ok to sign off when this fire alarm work is completed/inspected.
|
FIR12-00433
| INSP-Final Inspection | 12/16/2015 | 12/17/2015 | 12/17/2015 9:36:52 AM | A | PASS |
|
|
Permit finaled
|
BLD15-04276
| FIRE-Final Inspection | 12/16/2015 | 12/17/2015 | 12/17/2015 8:51:14 AM | A | PASS |
|
|
life safety passed
|
FIR15-00626
| INSP-Sprinkler Rough-in/Hydro | 12/16/2015 | 12/17/2015 | 12/17/2015 8:12:50 AM | A | PASS |
|
|
permit finaled
|
BLD15-02700
| FIRE-Final Inspection | 12/16/2015 | 12/17/2015 | 12/17/2015 8:12:10 AM | A | PASS |
|
|
life safety passed
|
NAF14-00002
| INSP-Sprinkler Rough-in/Hydro | 12/16/2015 | 12/17/2015 | 12/16/2015 4:32:45 PM | P | CANC |
|
|
Testing Phone #: ###-#### >> Inspection requested via web by Stan Beus Inspection cancelled from web by: Stan Beus
|
FIR15-00618
| INSP-Alarm Testing | 12/14/2015 | 12/17/2015 | 12/14/2015 5:14:03 PM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Brian Richard Inspection cancelled from web by: Brian Richard
|