Inspections for the day of: Tuesday, December 17, 2019.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-04812 Final12/17/201912/17/201912/17/2019 3:49:16 PMPPASS
furnace ac coil co ok
MEC19-05528 DOC - Permit Finaled12/17/201912/17/201912/17/2019 3:45:50 PMPPASS
final ok
MEC19-05528 Pressure Test12/17/201912/17/201912/17/2019 3:44:39 PMPPASS
call ###-#### for any questions Phone #: ###-#### Inspection requested via web by brett hoopes
- 20lb gas pressure test
- tagged meter
MEC19-05096 Rough-in12/17/201912/17/201912/17/2019 3:20:58 PMPPASS
Requesting cover inspection. Please contact Robbie prior to arrival to jobsite.
Robbie ###-#### Phone #: ###-#### Inspection requested via web by Commercial Coordinator
- R/I ok
- small amount of return duct and fresh air connection is exposed in garage can be seen at later date
MEC19-05500 Final12/17/201912/17/201912/17/2019 2:47:00 PMPPASS
Julee is available after 2:30pm for inspection. Phone #: ###-#### Inspection requested via web by Andrea Grigsby
- furnace flue ok
- final ok
MEC19-02879 Pressure Test12/16/201912/17/201912/17/2019 2:23:13 PMPFAIL
Need another gas pressure test as the project changed to two gaslines Inspection requested via web by yuriy kryachun
- This permit is for shell and core only. If 1st floor is being built out then a new permit is required. The 1st floor build out will also need to be reviewed by the City of Boise and a stamped set of prints onsite for inspection
- both gas lines outside need supported to wall
MEC19-04647 Final12/17/201912/17/201912/17/2019 1:50:59 PMPFAIL
Phone #: ###-#### Inspection requested via web by Matthew BLANKENSHIP
- condensate pump needs safety wired
- line set needs UV protection
- A/C needs weather tight conduit
- locking caps installed on service ports of A/C
MEC19-05346 Final12/13/201912/17/201912/17/2019 1:24:23 PMPFAIL
This is a Flue Pressure and Final Inspect. Please meet our installer
at home at 1:30 PM . Contact for Right Now is Mary ###-####
Phone #: ###-#### Inspection requested via web by Mary LaFayette
- 5lb flue pressure test fail
MEC19-05597 Rough-in12/17/201912/17/201912/17/2019 1:08:03 PMPFAIL
rough in inspection. Phone #: ###-#### Inspection requested via web by jeremy wanders
- crawl needs finished
- fresh air can't terminate out roof
- 5lb flue test
- dryer vent needs one more seam sealed
- crawl ventilation duct needs sealed
MEC19-05597 Pressure Test12/17/201912/17/201912/17/2019 1:06:20 PMPFAIL
20 lb test. low psi natural gas. Phone #: ###-#### Inspection requested via web by jeremy wanders
- gauge would not zero out
- penetration needs 10 mill tape installed
- re test
MEC19-02964 Pressure Test12/16/201912/17/201912/17/2019 10:59:35 AMAPASS
Adrian Phone #: ###-####
- 2 60lb gas pressure tests one to new water heater and one to kitcken ok
- still need to see updated and stamped prints onsite
-performed gas pressure tests to get heat back to building
MEC19-04812 Final12/16/201912/17/201912/17/2019 10:10:23 AMAFAIL
Please call Pat ###-#### or ###-#### when in route Phone #: ###-#### Inspection requested via web by Justin Osterhout
- line set needs insulation installed at indoor coil
MEC19-02273 Mec-Aging Inspection12/17/201912/17/201912/17/2019 9:43:43 AM FAIL
Reschedule inspection with homeowner to check co sensor. Permit has not been active since
7-3-19
MEC19-01922 Mec-Aging Inspection12/17/201912/17/201912/17/2019 9:42:12 AM FAIL
Need to re schedule inspection once corrections have been made. This permit has not been active since failing on 9-18-19
MEC19-05093 Rough-in12/16/201912/17/201912/17/2019 9:37:30 AMAPASS
Cover Inspection. Please contact Robbie at ###-#### prior to arrival. Phone #: ###-#### Inspection requested via web by Commercial Coordinator
- R/I ok
- small amount of return duct and fresh air connection is exposed in garage can be seen at later date
MEC19-05095 Rough-in12/16/201912/17/201912/17/2019 9:37:05 AMAPASS
Request cover inspection. Please contact Robbie at ###-#### prior to arrival. Phone #: ###-#### Inspection requested via web by Commercial Coordinator
- R/I ok
- small amount of return duct and fresh air connection is exposed in garage can be seen at later date
MEC19-05096 Rough-in12/16/201912/17/201912/17/2019 9:34:21 AMANR
Requesting cover inspection. Please contact Robbie prior to arrival to jobsite.
Robbie ###-#### Phone #: ###-#### Inspection requested via web by Commercial Coordinator
- not ready range vent needs installed. rescheduled with Robbie he said he would have it done this afternoon
MEC19-05539 Rough-in12/16/201912/17/201912/17/2019 8:51:57 AMAPASS
Garage Code 2468 - Builder ###-#### - HVAC ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
- R/I ok