Inspections for the day of: Friday, December 18, 2009.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-03244 ELE-Aging Inspection12/18/200912/18/200912/22/2009 8:51:32 AM CANC
ELE07-02885 ELE-Aging Inspection12/18/200912/18/200912/18/2009 3:02:32 PM CANC
ELE07-02885 DOC - Permit Expired12/18/200912/18/200912/18/2009 3:02:27 PMPPASS
no action
ELE09-02427 Permanent Service12/18/200912/18/200912/18/2009 2:31:35 PMPPASS
robert Phone #: ###-#### p/s o/h new ok
ELE09-02427 Final12/18/200912/18/200912/18/2009 2:30:48 PMPPASS
robert Phone #: ###-#### needs 40 amp max breaker called
ELE09-02426 Electrical Rough-In12/17/200912/18/200912/18/2009 1:50:49 PMPCANC
Steve Phone #: ###-#### see added r/i p/s
ELE09-02426 Rough-In Permanent Service12/18/200912/18/200912/18/2009 1:50:21 PMPPASS
Steve Phone #: ###-#### note sauna not there yet, r/i p/s o/h new ok
ELE09-02416 Permanent Service12/16/200912/18/200912/18/2009 12:45:32 PMPFAIL
dan Phone #: ###-#### met contr, correction posted art. 220 shall calc p/s for correct size needs 200 amp ?, 240.24 (D) panel not allowed in clothes closet
ELE09-01485 Final12/17/200912/18/200912/18/2009 10:45:35 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Lloyd Looney survey posted box fill needs recept left of cabinet in din rm ok called
ELE09-01520 Final12/18/200912/18/200912/18/2009 10:25:26 AMAPASS
ELE09-02415 Permanent Service12/17/200912/18/200912/18/2009 9:49:34 AMAFAIL
New permanent service inspection. For Idaho power swing. Existing service and all existing wiring in house will be gone after power is switched over. Sunroom on back of house is to be demolished. Incoming water pipe is plastic. Phone #: ###-#### Internet Inspection Request from: Joe Thomas corr. called needs listed or plastic conn. for GEC 312.5(C) exception ser cable not allowed in conduit out the bottom of panel, no access to inside of house
GCE09-00044 GCE-Rough-In12/18/200912/18/200912/18/2009 9:15:53 AMPNR
zen Phone #: ###-#### see am request
GCE09-00044 GCE-Rough-In12/17/200912/18/200912/18/2009 8:55:44 AMANR
Contact Zen @###-#### still needs fire alarm system dropped to new hard ceiling, too many 4 sq extensions on exit light boxes also free length of conductor met contr on job
ELE07-02179 DOC - Permit Expired12/18/200912/18/200912/18/2009 8:06:40 AMAPASS
no action for almost 2 years
ELE09-01914 Final12/17/200912/18/200912/17/2009 2:55:07 PMAPASS
Phone #: ###-#### Internet Inspection Request from: Therrin Robertson
ELE09-01915 Final12/17/200912/18/200912/17/2009 2:54:44 PMAPASS
Phone #: ###-#### Internet Inspection Request from: Therrin Robertson